2011Sexually Transmitted InfectionsOpen access

P3-S1.22 Evaluation of performance of six commercial assays for detection of characterised isolates ofNeisseria gonorrhoeaeand otherNeisseria spp.

S N Tabrizi, Magnus Unemo, Athena Limnios, Stig Ove Hjelmevoll, Suzanne M. Garland, John Tapsall

Open full text 0 citations

Abstract

Background Molecular detection ofNeisseria gonorrhoeaein urogenital samples is now routinely conducted in many diagnostic laboratories with the demand also expanding to testing of extragenital samples. Testing of extragenital samples poses a challenge as it may result in false positive results due to cross-reaction with commensalNeisseria spp.andN meningitidis. Adequate evaluation of molecular assays is essential prior to expanding utilisation of the assays to such specimens. Method This study aimed to examine 450 characterised clinical isolates comprising of 216N gonorrhoeaeand 234 otherNeisseria spp.and closely related bacteria from various geographical regions worldwide with six commercial assays including GenProbe APTIMA Combo 2 and APTIMA GC; Roche COBAS Amplicor CT/NG and COBAS 4800 CT/NG; BD ProbeTec GC Qx Amplified DNA Assay and Abbott RealTime CT/NG. Results Among 216N gonorrhoeaeisolates included in the study, all assays except COBAS Amplicor where four (1.9%) gonococcus isolates were not detected, showed a positive result with allN gonorrhoeaeisolates. Among 234Neisseria spp.evaluated, initial results showed all assays evaluated to display cross reaction with non-gonococcal Neisseria isolates. COBAS Amplicor and ProbeTec showed highest number of false positives, detecting 33 (14.1%) and 26 (11%) non-gonococcal Neisseria isolates respectively. Abbott RealTime, APTIMA Combo and APTIMA GC, and Roche COBAS 4800 showed initially low level of cross reaction, that is, detected 2 (1%), 5 (2.1%), 4 (1.7%) and 2 (1%) of the isolates respectively. When retested by the company using a fresh culture, none of these nine isolates showed cross reaction with the respective assays. Conclusion COBAS Amplicor and ProbeTec displayed highest number of false positives among assays evaluated, with the remaining assays only showing sporadic low level false positivity. Especially when examining extragenital specimens, supplementary testing for all assays and platforms remains recommended.

Open-access reader

About this research paper

What this paper is about

Background Molecular detection ofNeisseria gonorrhoeaein urogenital samples is now routinely conducted in many diagnostic laboratories with the demand also expanding to testing of extragenital samples. Testing of extragenital samples poses a challenge as it may result in false positive results due to cross-reaction with commensalNeisseria spp.andN meningitidis. Adequate evaluation of molecular assays is essential prior to expanding utilisation of the assays to such specimens. Method This study aimed to examine 450 characterised clinical isolates comprising of 216N gonorrhoeaeand 234 otherNeisseria spp.and closely related bacteria from various geographical regions worldwide with six commercial assays including GenProbe APTIMA Combo 2 and APTIMA GC; Roche COBAS Amplicor CT/NG and COBAS 4800 CT/NG; BD ProbeTec GC Qx Amplified DNA Assay and Abbott RealTime CT/NG. Results Among 216N gonorrhoeaeisolates included in the study, all assays except COBAS Amplicor where four (1.9%) gonococcus isolates were not detected, showed a positive result with allN gonorrhoeaeisolates. Among 234Neisseria spp.evaluated, initial results showed all assays evaluated to display cross reaction with non-gonococcal Neisseria isolates. COBAS Amplicor and ProbeTec showed highest number of false positives, detecting 33 (14.1%) and 26 (11%) non-gonococcal Neisseria isolates respectively. Abbott RealTime, APTIMA Combo and APTIMA GC, and Roche COBAS 4800 showed initially low level of cross reaction, that is, detected 2 (1%), 5 (2.1%), 4 (1.7%) and 2 (1%) of the isolates respectively. When retested by the company using a fresh culture, none of these nine isolates showed cross reaction with the respective assays. Conclusion COBAS Amplicor and ProbeTec displayed highest number of false positives among assays evaluated, with the remaining assays only showing sporadic low level false positivity. Especially when examining extragenital specimens, supplementary testing for all assays and platforms remains recommended.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Background Molecular detection ofNeisseria gonorrhoeaein urogenital samples is now routinely conducted in many diagnostic laboratories with the demand also expanding to testing of extragenital samples. Testing of extragenital samples poses a challenge as it may result in false positive results due to cross-reaction with commensalNeisseria spp.andN meningitidis. Adequate evaluation of molecular assays is essential prior to expanding utilisation of the assays to such specimens. Method This study aimed to examine 450 characterised clinical isolates comprising of 216N gonorrhoeaeand 234 otherNeisseria spp.and closely related bacteria from various geographical regions worldwide with six commercial assays including GenProbe APTIMA Combo 2 and APTIMA GC; Roche COBAS Amplicor CT/NG and COBAS 4800 CT/NG; BD ProbeTec GC Qx Amplified DNA Assay and Abbott RealTime CT/NG. Results Among 216N gonorrhoeaeisolates included in the study, all assays except COBAS Amplicor where four (1.9%) gonococcus isolates were not detected, showed a positive result with allN gonorrhoeaeisolates. Among 234Neisseria spp.evaluated, initial results showed all assays evaluated to display cross reaction with non-gonococcal Neisseria isolates. COBAS Amplicor and ProbeTec showed highest number of false positives, detecting 33 (14.1%) and 26 (11%) non-gonococcal Neisseria isolates respectively. Abbott RealTime, APTIMA Combo and APTIMA GC, and Roche COBAS 4800 showed initially low level of cross reaction, that is, detected 2 (1%), 5 (2.1%), 4 (1.7%) and 2 (1%) of the isolates respectively. When retested by the company using a fresh culture, none of these nine isolates showed cross reaction with the respective assays. Conclusion COBAS Amplicor and ProbeTec displayed highest number of false positives among assays evaluated, with the remaining assays only showing sporadic low level false positivity. Especially when examining extragenital specimens, supplementary testing for all assays and platforms remains recommended.

Key concepts: Neisseria gonorrhoeae, Neisseria, Microbiology, Neisseria meningitidis, Neisseriaceae, Gonorrhea, Medicine, Virology

Related papers

Back to paper searchBrowse research topicsOriginal source
P3-S1.22 Evaluation of performance of six commercial assays for detection of characterised isolates ofNeisseria gonorrhoeaeand otherNeisseria spp. — Research Paper | ScholarLens