2012•Circulation Arrhythmia and ElectrophysiologyOpen access

Inverse Solution Mapping of Epicardial Potentials

John L. Sapp, Fady Dawoud, John Clements, B. Milan Horáček

Open full text 97 citations

Abstract

BACKGROUND: Catheter ablation of ventricular tachycardia (VT) is still one of the most challenging procedures in cardiac electrophysiology, limited, in part, by unmappable arrhythmias that are nonsustained or poorly tolerated. Calculation of the inverse solution from body surface potential mapping (sometimes known as ECG imaging) has shown tremendous promise and can rapidly map these arrhythmias, but we lack quantitative assessment of its accuracy in humans. We compared inverse solution mapping with computed tomography-registered electroanatomic epicardial contact catheter mapping to study the resolution of this technique, the influence of myocardial scar, and the ability to map VT. METHODS AND RESULTS: For 4 patients undergoing epicardial catheter mapping and ablation of VT, 120-lead body surface potential mappings were obtained during implantable defibrillator pacing, catheter pacing from 79 epicardial sites, and induced VT. Inverse epicardial electrograms computed using individualized torso/epicardial surface geometries extracted from computed tomography images were compared with registered electroanatomic contact maps. The distance between estimated and actual epicardial pacing sites was 13 ± 9 mm over normal myocardium with no stimulus-QRS delay but increased significantly over scar (P=0.013) or was close to scar (P=0.014). Contact maps during right ventricular pacing correlated closely to inverse solution isochrones. Maps of inverse epicardial potentials during 6 different induced VTs indicated areas of earliest activation, which correlated closely with clinically identified VT exit sites for 2 epicardial VTs. CONCLUSIONS: Inverse solution maps can identify sites of epicardial pacing with good accuracy, which diminishes over myocardial scar or over slowly conducting tissue. This approach can also identify epicardial VT exit sites and ventricular activation sequences.

Open-access reader

About this research paper

What this paper is about

BACKGROUND: Catheter ablation of ventricular tachycardia (VT) is still one of the most challenging procedures in cardiac electrophysiology, limited, in part, by unmappable arrhythmias that are nonsustained or poorly tolerated. Calculation of the inverse solution from body surface potential mapping (sometimes known as ECG imaging) has shown tremendous promise and can rapidly map these arrhythmias, but we lack quantitative assessment of its accuracy in humans. We compared inverse solution mapping with computed tomography-registered electroanatomic epicardial contact catheter mapping to study the resolution of this technique, the influence of myocardial scar, and the ability to map VT. METHODS AND RESULTS: For 4 patients undergoing epicardial catheter mapping and ablation of VT, 120-lead body surface potential mappings were obtained during implantable defibrillator pacing, catheter pacing from 79 epicardial sites, and induced VT. Inverse epicardial electrograms computed using individualized torso/epicardial surface geometries extracted from computed tomography images were compared with registered electroanatomic contact maps. The distance between estimated and actual epicardial pacing sites was 13 ± 9 mm over normal myocardium with no stimulus-QRS delay but increased significantly over scar (P=0.013) or was close to scar (P=0.014). Contact maps during right ventricular pacing correlated closely to inverse solution isochrones. Maps of inverse epicardial potentials during 6 different induced VTs indicated areas of earliest activation, which correlated closely with clinically identified VT exit sites for 2 epicardial VTs. CONCLUSIONS: Inverse solution maps can identify sites of epicardial pacing with good accuracy, which diminishes over myocardial scar or over slowly conducting tissue. This approach can also identify epicardial VT exit sites and ventricular activation sequences.

Why it matters

OpenAlex reports 97 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Catheter ablation of ventricular tachycardia (VT) is still one of the most challenging procedures in cardiac electrophysiology, limited, in part, by unmappable arrhythmias that are nonsustained or poorly tolerated. Calculation of the inverse solution from body surface potential mapping (sometimes known as ECG imaging) has shown tremendous promise and can rapidly map these arrhythmias, but we lack quantitative assessment of its accuracy in humans. We compared inverse solution mapping with computed tomography-registered electroanatomic epicardial contact catheter mapping to study the resolution of this technique, the influence of myocardial scar, and the ability to map VT. METHODS AND RESULTS: For 4 patients undergoing epicardial catheter mapping and ablation of VT, 120-lead body surface potential mappings were obtained during implantable defibrillator pacing, catheter pacing from 79 epicardial sites, and induced VT. Inverse epicardial electrograms computed using individualized torso/epicardial surface geometries extracted from computed tomography images were compared with registered electroanatomic contact maps. The distance between estimated and actual epicardial pacing sites was 13 ± 9 mm over normal myocardium with no stimulus-QRS delay but increased significantly over scar (P=0.013) or was close to scar (P=0.014). Contact maps during right ventricular pacing correlated closely to inverse solution isochrones. Maps of inverse epicardial potentials during 6 different induced VTs indicated areas of earliest activation, which correlated closely with clinically identified VT exit sites for 2 epicardial VTs. CONCLUSIONS: Inverse solution maps can identify sites of epicardial pacing with good accuracy, which diminishes over myocardial scar or over slowly conducting tissue. This approach can also identify epicardial VT exit sites and ventricular activation sequences.

Key concepts: Medicine, Ventricular tachycardia, Catheter ablation, Ablation, Cardiology, Torso, Internal medicine, Endocardium

Related papers

Back to paper searchBrowse research topicsOriginal source
Inverse Solution Mapping of Epicardial Potentials — Research Paper | ScholarLens