2012•Chinese Journal of Optics and Applied OpticsRequires access

Design of standard head-mounted display for test system calibration

李灿 Li Can, 孙强 Sun Qiang, 宋淑梅 SONG Shu-mei, 李淳 Li Chun, 王鹤 Wang He

Open publisher page 0 citations

Abstract

To calibrate the test instrument of a Head-Mounted Display(HMD),a standard HMD optical system with a simple configuration and ascendant optical performance is proposed.In the limited space avoilable,the optical system is designed with only a spherical surface and an on-axial scheme to meet the requirements of low distortion and high resolution.By the symmetry principle of optical design,most aberrations of the standard HMD system can be corrected synthetically.The standard HMD system is used twice so that the system has a sharp exit pupil.The standard HMD system has a designed for a 0.5 inch Cathode Ray Tube(CRT) with a field of view 30° and an exit pupil distance of 75 mm.The MTF at 30 lp/mm resolution across the entire field of view is more than 0.3,and the maximum distortion is less than 0.9%.The designed standard HMD has a simple layout and compact structure,and the obtained results confirm the feasibility of the new system.

About this research paper

What this paper is about

To calibrate the test instrument of a Head-Mounted Display(HMD),a standard HMD optical system with a simple configuration and ascendant optical performance is proposed.In the limited space avoilable,the optical system is designed with only a spherical surface and an on-axial scheme to meet the requirements of low distortion and high resolution.By the symmetry principle of optical design,most aberrations of the standard HMD system can be corrected synthetically.The standard HMD system is used twice so that the system has a sharp exit pupil.The standard HMD system has a designed for a 0.5 inch Cathode Ray Tube(CRT) with a field of view 30° and an exit pupil distance of 75 mm.The MTF at 30 lp/mm resolution across the entire field of view is more than 0.3,and the maximum distortion is less than 0.9%.The designed standard HMD has a simple layout and compact structure,and the obtained results confirm the feasibility of the new system.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

To calibrate the test instrument of a Head-Mounted Display(HMD),a standard HMD optical system with a simple configuration and ascendant optical performance is proposed.In the limited space avoilable,the optical system is designed with only a spherical surface and an on-axial scheme to meet the requirements of low distortion and high resolution.By the symmetry principle of optical design,most aberrations of the standard HMD system can be corrected synthetically.The standard HMD system is used twice so that the system has a sharp exit pupil.The standard HMD system has a designed for a 0.5 inch Cathode Ray Tube(CRT) with a field of view 30° and an exit pupil distance of 75 mm.The MTF at 30 lp/mm resolution across the entire field of view is more than 0.3,and the maximum distortion is less than 0.9%.The designed standard HMD has a simple layout and compact structure,and the obtained results confirm the feasibility of the new system.

Key concepts: Distortion (music), Optical head-mounted display, Exit pupil, Optics, Computer science, Calibration, Head (geology), Field of view

Related papers

Back to paper searchBrowse research topicsOriginal source
Design of standard head-mounted display for test system calibration — Research Paper | ScholarLens