1999•Journal of Computer Assisted TomographyRequires access

Correlation of Regional Cerebral Blood Flow Measured by Stable Xenon CT and Perfusion MRI

Thomas Hagen, K. Bartylla, Uwe Piepgras

Open publisher page 63 citations

Abstract

PURPOSE: The purpose of this work was to investigate the validity of perfusion MRI in comparison with stable xenon CT for evaluating regional cerebral blood flow (rCBF). METHOD: The rCBF was measured by xenon CT and perfusion MRI within a 24 h interval in 10 patients (mean +/- SD age 63 +/- 10 years). For perfusion MRI, absolute values of rCBF were calculated based on the indicator dilution theory after injection of 0.1 mmol/kg of Gd-DTPA. Eight to 10 regions of interest (37 mm2) were located in the white and gray matter on the rCBF images for each of the 10 patients. RESULTS: The mean +/- SD values of rCBF in gray matter were 48.5 +/- 14.1 ml/100 g/min measured by xenon CT and 52.2 +/- 16.4 ml/100 g/min measured by perfusion MRI. In the white matter, the rCBF was 22.6 +/- 9.1 ml/100 g/min by xenon CT and 27.4 +/- 6.8 ml/100 g/min by perfusion MRI. There was a good correlation of rCBF values between perfusion MRI and xenon CT (Pearson correlation coefficient 0.83; p < 0.0001). CONCLUSION: Comparable to xenon CT, perfusion MRI provides relatively high resolution, quantitative local rCBF information coupled to MR anatomy.

About this research paper

What this paper is about

PURPOSE: The purpose of this work was to investigate the validity of perfusion MRI in comparison with stable xenon CT for evaluating regional cerebral blood flow (rCBF). METHOD: The rCBF was measured by xenon CT and perfusion MRI within a 24 h interval in 10 patients (mean +/- SD age 63 +/- 10 years). For perfusion MRI, absolute values of rCBF were calculated based on the indicator dilution theory after injection of 0.1 mmol/kg of Gd-DTPA. Eight to 10 regions of interest (37 mm2) were located in the white and gray matter on the rCBF images for each of the 10 patients. RESULTS: The mean +/- SD values of rCBF in gray matter were 48.5 +/- 14.1 ml/100 g/min measured by xenon CT and 52.2 +/- 16.4 ml/100 g/min measured by perfusion MRI. In the white matter, the rCBF was 22.6 +/- 9.1 ml/100 g/min by xenon CT and 27.4 +/- 6.8 ml/100 g/min by perfusion MRI. There was a good correlation of rCBF values between perfusion MRI and xenon CT (Pearson correlation coefficient 0.83; p < 0.0001). CONCLUSION: Comparable to xenon CT, perfusion MRI provides relatively high resolution, quantitative local rCBF information coupled to MR anatomy.

Why it matters

OpenAlex reports 63 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: The purpose of this work was to investigate the validity of perfusion MRI in comparison with stable xenon CT for evaluating regional cerebral blood flow (rCBF). METHOD: The rCBF was measured by xenon CT and perfusion MRI within a 24 h interval in 10 patients (mean +/- SD age 63 +/- 10 years). For perfusion MRI, absolute values of rCBF were calculated based on the indicator dilution theory after injection of 0.1 mmol/kg of Gd-DTPA. Eight to 10 regions of interest (37 mm2) were located in the white and gray matter on the rCBF images for each of the 10 patients. RESULTS: The mean +/- SD values of rCBF in gray matter were 48.5 +/- 14.1 ml/100 g/min measured by xenon CT and 52.2 +/- 16.4 ml/100 g/min measured by perfusion MRI. In the white matter, the rCBF was 22.6 +/- 9.1 ml/100 g/min by xenon CT and 27.4 +/- 6.8 ml/100 g/min by perfusion MRI. There was a good correlation of rCBF values between perfusion MRI and xenon CT (Pearson correlation coefficient 0.83; p < 0.0001). CONCLUSION: Comparable to xenon CT, perfusion MRI provides relatively high resolution, quantitative local rCBF information coupled to MR anatomy.

Key concepts: Medicine, Xenon, Cerebral blood flow, Perfusion, Nuclear medicine, Cerebral perfusion pressure, Perfusion scanning, Blood flow

Related papers

Back to paper searchBrowse research topicsOriginal source
Correlation of Regional Cerebral Blood Flow Measured by Stable Xenon CT and Perfusion MRI — Research Paper | ScholarLens