2010•Radiation Protection DosimetryRequires access

Occupational exposure doses in interventional procedures in Bosnia and Herzegovina

Begzada Basic, Adnan Beganović, Amra Skopljak-Beganović, Davorin Samek

Open publisher page 10 citations

Abstract

Monitoring of occupationally exposed workers in Bosnia and Herzegovina started in 1960s and it was interrupted in 1992. Dosimetry service resumed in 1999 when the International Atomic Energy Agency provided Radiation Protection Centre with Harshaw 4500 Thermoluminescence dosemeter (TLD)-reader and the first set of TLDs. The highest doses are received by professionals working in interventional procedures (radiology, cardiology, gastroenterohepatology etc.). Number of these procedures is increasing each year (just in cardiology this increase is 24 % per year). Results from two TLDs are used to estimate effective dose. One is worn under the apron (chest level), and the other above (neck level). Calculation is performed using Niklason's methodology. Total number of occupationally exposed persons in interventional radiology is 90. The collective dose they receive is 67 person mSv, while the mean dose is 0.77 mSv (based on 12-month period). Highest doses are received by physicians (3.7 mSv), while radiographers and nurses receive 2.1 and 1.9 mSv respectively. This occurs due to the fact that physicians stand closer to the source (patient). The lead apron is proven to be the most efficient radiation protection equipment, but, also, lead thyroid shield and glasses can significantly lower doses received by professionals. The use of this equipment is highly recommended.

About this research paper

What this paper is about

Monitoring of occupationally exposed workers in Bosnia and Herzegovina started in 1960s and it was interrupted in 1992. Dosimetry service resumed in 1999 when the International Atomic Energy Agency provided Radiation Protection Centre with Harshaw 4500 Thermoluminescence dosemeter (TLD)-reader and the first set of TLDs. The highest doses are received by professionals working in interventional procedures (radiology, cardiology, gastroenterohepatology etc.). Number of these procedures is increasing each year (just in cardiology this increase is 24 % per year). Results from two TLDs are used to estimate effective dose. One is worn under the apron (chest level), and the other above (neck level). Calculation is performed using Niklason's methodology. Total number of occupationally exposed persons in interventional radiology is 90. The collective dose they receive is 67 person mSv, while the mean dose is 0.77 mSv (based on 12-month period). Highest doses are received by physicians (3.7 mSv), while radiographers and nurses receive 2.1 and 1.9 mSv respectively. This occurs due to the fact that physicians stand closer to the source (patient). The lead apron is proven to be the most efficient radiation protection equipment, but, also, lead thyroid shield and glasses can significantly lower doses received by professionals. The use of this equipment is highly recommended.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Monitoring of occupationally exposed workers in Bosnia and Herzegovina started in 1960s and it was interrupted in 1992. Dosimetry service resumed in 1999 when the International Atomic Energy Agency provided Radiation Protection Centre with Harshaw 4500 Thermoluminescence dosemeter (TLD)-reader and the first set of TLDs. The highest doses are received by professionals working in interventional procedures (radiology, cardiology, gastroenterohepatology etc.). Number of these procedures is increasing each year (just in cardiology this increase is 24 % per year). Results from two TLDs are used to estimate effective dose. One is worn under the apron (chest level), and the other above (neck level). Calculation is performed using Niklason's methodology. Total number of occupationally exposed persons in interventional radiology is 90. The collective dose they receive is 67 person mSv, while the mean dose is 0.77 mSv (based on 12-month period). Highest doses are received by physicians (3.7 mSv), while radiographers and nurses receive 2.1 and 1.9 mSv respectively. This occurs due to the fact that physicians stand closer to the source (patient). The lead apron is proven to be the most efficient radiation protection equipment, but, also, lead thyroid shield and glasses can significantly lower doses received by professionals. The use of this equipment is highly recommended.

Key concepts: Lead apron, Medicine, Thermoluminescent dosimeter, Radiation protection, Occupational exposure, Interventional radiology, Effective dose (radiation), Dosimetry

Related papers

Back to paper searchBrowse research topicsOriginal source
Occupational exposure doses in interventional procedures in Bosnia and Herzegovina — Research Paper | ScholarLens