1971Unpublished venueOpen access

COMPARISON OF CALCULATED AND MEASURED VALUES OF rho28 AND delta25 28 FOR 26 LATTICES OF UO 2 RODS IN A LIGHT WATER MODERATOR.

Battelle Pacific Northwest Labs., Richland, Wash. (USA), D Oden, USDOE

Open full text 0 citations

Abstract

A study was undertaken to test the adequacy of current theoretical models used to predict 238U reaction rates in uniform lattice cells containing U0 2 rods in a light water moderator.Calculations were made 28 with two analytical models on data for 26 lattices for which p28 and 025 had been measured.Larqe discrepancies were observed between the measured and calculated results which could be attributed to systematic experimental errors and/or biases in the analytical models.The influence that the typical discrepancies observed would have on the calculated eigenvalue was demonstrated to be appreciable and would generally lead to an underprediction of this quantity, especially for undermoderated lattices.It is recommended that a more detailed study be undertaken to determine the cause of the differences observed between theory and experiment.

Open-access reader

About this research paper

What this paper is about

A study was undertaken to test the adequacy of current theoretical models used to predict 238U reaction rates in uniform lattice cells containing U0 2 rods in a light water moderator.Calculations were made 28 with two analytical models on data for 26 lattices for which p28 and 025 had been measured.Larqe discrepancies were observed between the measured and calculated results which could be attributed to systematic experimental errors and/or biases in the analytical models.The influence that the typical discrepancies observed would have on the calculated eigenvalue was demonstrated to be appreciable and would generally lead to an underprediction of this quantity, especially for undermoderated lattices.It is recommended that a more detailed study be undertaken to determine the cause of the differences observed between theory and experiment.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A study was undertaken to test the adequacy of current theoretical models used to predict 238U reaction rates in uniform lattice cells containing U0 2 rods in a light water moderator.Calculations were made 28 with two analytical models on data for 26 lattices for which p28 and 025 had been measured.Larqe discrepancies were observed between the measured and calculated results which could be attributed to systematic experimental errors and/or biases in the analytical models.The influence that the typical discrepancies observed would have on the calculated eigenvalue was demonstrated to be appreciable and would generally lead to an underprediction of this quantity, especially for undermoderated lattices.It is recommended that a more detailed study be undertaken to determine the cause of the differences observed between theory and experiment.

Key concepts: Rod, Moderation, Materials science, Analytical Chemistry (journal), Chemistry, Mathematics, Statistics, Chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source