2015•The Journal of Vascular AccessRequires access

Which Arm and Vein are more Appropriate for Single-Step, Non-Fluoroscopic, Peripherally Inserted Central Catheter Insertion?

Eui-Yong Jeon, Young K. Cho, Dae Young Yoon, Jin Ho Hwang

Open publisher page 21 citations

Abstract

OBJECTIVE: We investigated which arm and vein led to the most successful outcomes during non-fluoroscopic peripherallyinserted central catheter (PICC) insertion. METHODS: A total of 743 cases from July 2012 to March 2014 were retrospectively reviewed. We also analyzed the following: 1) accessed arm (right or left), 2) accessed vein (cephalic, basilic, or brachial), 3) primary and secondary success rates, 4) causes of failure (location of obstacles), and 5) problemsolving methods for catheter repositioning. RESULTS: The primary success rate was 46.3% (344/743) with 49.4% (123/249) on the right arm and 44.7% (273/494) on the left arm. The secondary success rate was 53.7% (399/743) with 50.6% (126/249) on the right arm and 55.3% (273/494) on the left arm. The causes of failure were 100% (43/43) for the left cephalic vein, 61.5% (8/13) for the right cephalic vein, 50.6% (43/85) for the left brachial vein, and 51.1% (23/45) for the right brachial vein, 51.1% (187/366) for the left basilic vein, and 49.7% (95/191) for the right basilic vein. The failure rate through the left cephalic vein was significantly higher than that for other veins. The most common locations of obstacles were the subclavian vein (28.8%, 115/399), axillary vein (24.3%, 97/399), and brachiocephalic vein (19.3%, 77/399). The most common problem-solving methods were with guidewire assistance (74.7%, 298/399), venographic guidance (13.8%, 55/399), and fluoroscopic guidance (11.5%, 46/399). CONCLUSIONS: Right-arm access through the basilic or brachial vein may be more appropriate for successful nonfluoroscopic PICC insertion compared with the access through the left arm and the cephalic vein.

About this research paper

What this paper is about

OBJECTIVE: We investigated which arm and vein led to the most successful outcomes during non-fluoroscopic peripherallyinserted central catheter (PICC) insertion. METHODS: A total of 743 cases from July 2012 to March 2014 were retrospectively reviewed. We also analyzed the following: 1) accessed arm (right or left), 2) accessed vein (cephalic, basilic, or brachial), 3) primary and secondary success rates, 4) causes of failure (location of obstacles), and 5) problemsolving methods for catheter repositioning. RESULTS: The primary success rate was 46.3% (344/743) with 49.4% (123/249) on the right arm and 44.7% (273/494) on the left arm. The secondary success rate was 53.7% (399/743) with 50.6% (126/249) on the right arm and 55.3% (273/494) on the left arm. The causes of failure were 100% (43/43) for the left cephalic vein, 61.5% (8/13) for the right cephalic vein, 50.6% (43/85) for the left brachial vein, and 51.1% (23/45) for the right brachial vein, 51.1% (187/366) for the left basilic vein, and 49.7% (95/191) for the right basilic vein. The failure rate through the left cephalic vein was significantly higher than that for other veins. The most common locations of obstacles were the subclavian vein (28.8%, 115/399), axillary vein (24.3%, 97/399), and brachiocephalic vein (19.3%, 77/399). The most common problem-solving methods were with guidewire assistance (74.7%, 298/399), venographic guidance (13.8%, 55/399), and fluoroscopic guidance (11.5%, 46/399). CONCLUSIONS: Right-arm access through the basilic or brachial vein may be more appropriate for successful nonfluoroscopic PICC insertion compared with the access through the left arm and the cephalic vein.

Why it matters

OpenAlex reports 21 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: We investigated which arm and vein led to the most successful outcomes during non-fluoroscopic peripherallyinserted central catheter (PICC) insertion. METHODS: A total of 743 cases from July 2012 to March 2014 were retrospectively reviewed. We also analyzed the following: 1) accessed arm (right or left), 2) accessed vein (cephalic, basilic, or brachial), 3) primary and secondary success rates, 4) causes of failure (location of obstacles), and 5) problemsolving methods for catheter repositioning. RESULTS: The primary success rate was 46.3% (344/743) with 49.4% (123/249) on the right arm and 44.7% (273/494) on the left arm. The secondary success rate was 53.7% (399/743) with 50.6% (126/249) on the right arm and 55.3% (273/494) on the left arm. The causes of failure were 100% (43/43) for the left cephalic vein, 61.5% (8/13) for the right cephalic vein, 50.6% (43/85) for the left brachial vein, and 51.1% (23/45) for the right brachial vein, 51.1% (187/366) for the left basilic vein, and 49.7% (95/191) for the right basilic vein. The failure rate through the left cephalic vein was significantly higher than that for other veins. The most common locations of obstacles were the subclavian vein (28.8%, 115/399), axillary vein (24.3%, 97/399), and brachiocephalic vein (19.3%, 77/399). The most common problem-solving methods were with guidewire assistance (74.7%, 298/399), venographic guidance (13.8%, 55/399), and fluoroscopic guidance (11.5%, 46/399). CONCLUSIONS: Right-arm access through the basilic or brachial vein may be more appropriate for successful nonfluoroscopic PICC insertion compared with the access through the left arm and the cephalic vein.

Key concepts: Basilic Vein, Cephalic vein, Medicine, Axillary vein, Subclavian vein, Vein, Catheter, Peripherally inserted central catheter

Related papers

Back to paper searchBrowse research topicsOriginal source
Which Arm and Vein are more Appropriate for Single-Step, Non-Fluoroscopic, Peripherally Inserted Central Catheter Insertion? — Research Paper | ScholarLens