2016American journal of clinical medicine researchOpen access

Intra-abdominal Pressure is Influenced by Body Position?

Sandra Lopes, Andreia Nunes, Maria M. R. E. Niza, Antonio Carlos Dourado

Open full text 2 citations

Abstract

Background: Increased intra-abdominal pressure (IAP) is a complication related to physio pathological changes with high rates of mortality and morbidity. Abdominal surgery is consider one of the risk factors that can increased IAP. Measurement can be done by direct or indirect methods, being the most used the transurethral (TM). However this method continues to generate some controversy. This study tries to clarify the doubts of the effect of body position when we use different methods to measure IAP. Methodology: Study realized an anatomical model in order to eliminate the described variables that influence IAP: abdominal and gastric contraction, micturition reflex and breathing. IAP was measured, directly, via microsensor and, indirectly, by TM and intragastric manometry, in five different body positions. The study population consists in a population of 29 anatomical model, 14 males and 15 females, with an average weight of 12.04 ± 5.67 kilograms (Kg). The inclusion criteria consisted in the absence of abdominal disease that would. Principal Findings: IAP determination by direct method showed no differences in the five body positions (P=0.765). The indirect method with better correlation with the direct was TM (cc0.87). Indirect methods revealed statistically significant differences with the direct, only in the Trendelenburg and reverse Trendelenburg. Conclusions: The clinical impact of this study is to decrease the doubts in the measurements of IAP. This study improves the knowledge of the application of the direct and indirect methods to accesses IAP. IAP is not affected by body position and the direct pressure value measured in all positions is constant. Only if the indirect methods are used, in Trendelenburg and reverse Trendelenburg positions, they may underestimate or overestimate IAP value. For the first time it was explained why this phenomenon occurs.

About this research paper

What this paper is about

Background: Increased intra-abdominal pressure (IAP) is a complication related to physio pathological changes with high rates of mortality and morbidity. Abdominal surgery is consider one of the risk factors that can increased IAP. Measurement can be done by direct or indirect methods, being the most used the transurethral (TM). However this method continues to generate some controversy. This study tries to clarify the doubts of the effect of body position when we use different methods to measure IAP. Methodology: Study realized an anatomical model in order to eliminate the described variables that influence IAP: abdominal and gastric contraction, micturition reflex and breathing. IAP was measured, directly, via microsensor and, indirectly, by TM and intragastric manometry, in five different body positions. The study population consists in a population of 29 anatomical model, 14 males and 15 females, with an average weight of 12.04 ± 5.67 kilograms (Kg). The inclusion criteria consisted in the absence of abdominal disease that would. Principal Findings: IAP determination by direct method showed no differences in the five body positions (P=0.765). The indirect method with better correlation with the direct was TM (cc0.87). Indirect methods revealed statistically significant differences with the direct, only in the Trendelenburg and reverse Trendelenburg. Conclusions: The clinical impact of this study is to decrease the doubts in the measurements of IAP. This study improves the knowledge of the application of the direct and indirect methods to accesses IAP. IAP is not affected by body position and the direct pressure value measured in all positions is constant. Only if the indirect methods are used, in Trendelenburg and reverse Trendelenburg positions, they may underestimate or overestimate IAP value. For the first time it was explained why this phenomenon occurs.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Background: Increased intra-abdominal pressure (IAP) is a complication related to physio pathological changes with high rates of mortality and morbidity. Abdominal surgery is consider one of the risk factors that can increased IAP. Measurement can be done by direct or indirect methods, being the most used the transurethral (TM). However this method continues to generate some controversy. This study tries to clarify the doubts of the effect of body position when we use different methods to measure IAP. Methodology: Study realized an anatomical model in order to eliminate the described variables that influence IAP: abdominal and gastric contraction, micturition reflex and breathing. IAP was measured, directly, via microsensor and, indirectly, by TM and intragastric manometry, in five different body positions. The study population consists in a population of 29 anatomical model, 14 males and 15 females, with an average weight of 12.04 ± 5.67 kilograms (Kg). The inclusion criteria consisted in the absence of abdominal disease that would. Principal Findings: IAP determination by direct method showed no differences in the five body positions (P=0.765). The indirect method with better correlation with the direct was TM (cc0.87). Indirect methods revealed statistically significant differences with the direct, only in the Trendelenburg and reverse Trendelenburg. Conclusions: The clinical impact of this study is to decrease the doubts in the measurements of IAP. This study improves the knowledge of the application of the direct and indirect methods to accesses IAP. IAP is not affected by body position and the direct pressure value measured in all positions is constant. Only if the indirect methods are used, in Trendelenburg and reverse Trendelenburg positions, they may underestimate or overestimate IAP value. For the first time it was explained why this phenomenon occurs.

Key concepts: Body position, Medicine, Trendelenburg, Trendelenburg position, Population, Body weight, Surgery, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Intra-abdominal Pressure is Influenced by Body Position? — Research Paper | ScholarLens