1990•Nuclear TechnologyRequires access

Loss-of-Coolant Accident Performance of the Westinghouse 600-MW(electric) Advanced Pressurized Water Reactor

Robert M. Kemper, Christine M. Vertes

Open publisher page 8 citations

Abstract

Emergency core cooling system performance analyses that demonstrate compliance with the 10CFR50.46 final acceptance criteria have been performed for the unique Westinghouse AP600 advanced pressurized water reactor. The AP600 plant features a low power density core, canned-motor reactor coolant pumps, passive safeguards systems, and an automatic depressurization system. It exhibits exceptional loss-of-coolant accident (LOCA) performance. A spectrum of small-break LOCA cases successfully depressurize while exhibiting no core uncovery; the maximum cladding temperature in each case is the initial steady-state value. The calculated peak cladding temperature for a design-basis large-break LOCA is only 1061 K at the design total peaking factor of 2.40.

About this research paper

What this paper is about

Emergency core cooling system performance analyses that demonstrate compliance with the 10CFR50.46 final acceptance criteria have been performed for the unique Westinghouse AP600 advanced pressurized water reactor. The AP600 plant features a low power density core, canned-motor reactor coolant pumps, passive safeguards systems, and an automatic depressurization system. It exhibits exceptional loss-of-coolant accident (LOCA) performance. A spectrum of small-break LOCA cases successfully depressurize while exhibiting no core uncovery; the maximum cladding temperature in each case is the initial steady-state value. The calculated peak cladding temperature for a design-basis large-break LOCA is only 1061 K at the design total peaking factor of 2.40.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Emergency core cooling system performance analyses that demonstrate compliance with the 10CFR50.46 final acceptance criteria have been performed for the unique Westinghouse AP600 advanced pressurized water reactor. The AP600 plant features a low power density core, canned-motor reactor coolant pumps, passive safeguards systems, and an automatic depressurization system. It exhibits exceptional loss-of-coolant accident (LOCA) performance. A spectrum of small-break LOCA cases successfully depressurize while exhibiting no core uncovery; the maximum cladding temperature in each case is the initial steady-state value. The calculated peak cladding temperature for a design-basis large-break LOCA is only 1061 K at the design total peaking factor of 2.40.

Key concepts: Nuclear engineering, Coolant, Loss-of-coolant accident, Cabin pressurization, Cladding (metalworking), Water cooling, Materials science, Pressurized water reactor

Related papers

Back to paper searchBrowse research topicsOriginal source
Loss-of-Coolant Accident Performance of the Westinghouse 600-MW(electric) Advanced Pressurized Water Reactor — Research Paper | ScholarLens