1974•Nuclear Science and EngineeringRequires access

Relative and Absolute Measurements of the Fast-Neutron Fission Cross Section of Uranium-235

Wolfgang P. Poenitz

Open publisher page 15 citations

Abstract

Measurements of the dependence of the 235U fission cross section on neutron energy were carried out in the energy range from 35 keV to 3.5 MeV. Three different techniques were applied to monitor the neutron flux. The 6Li(n,α)T cross section was utilized in the lower energy range (<110 keV). The grey neutron detector was employed in the entire energy range, and the black neutron detector was used above 400 keV. The shapes were normalized with the results obtained from three different sets of absolute cross-section measurements. The associated activity technique was applied in the 450- to 650-keV range, the black neutron detector was used for absolute flux measurements at 800 keV and 3.5 MeV, and a calibrated vanadium bath was used at 500 keV. The results from the present measurements agree well with more recent data obtained by other experimenters but differ up to a factor of 2 from older values.

About this research paper

What this paper is about

Measurements of the dependence of the 235U fission cross section on neutron energy were carried out in the energy range from 35 keV to 3.5 MeV. Three different techniques were applied to monitor the neutron flux. The 6Li(n,α)T cross section was utilized in the lower energy range (<110 keV). The grey neutron detector was employed in the entire energy range, and the black neutron detector was used above 400 keV. The shapes were normalized with the results obtained from three different sets of absolute cross-section measurements. The associated activity technique was applied in the 450- to 650-keV range, the black neutron detector was used for absolute flux measurements at 800 keV and 3.5 MeV, and a calibrated vanadium bath was used at 500 keV. The results from the present measurements agree well with more recent data obtained by other experimenters but differ up to a factor of 2 from older values.

Why it matters

OpenAlex reports 15 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Measurements of the dependence of the 235U fission cross section on neutron energy were carried out in the energy range from 35 keV to 3.5 MeV. Three different techniques were applied to monitor the neutron flux. The 6Li(n,α)T cross section was utilized in the lower energy range (<110 keV). The grey neutron detector was employed in the entire energy range, and the black neutron detector was used above 400 keV. The shapes were normalized with the results obtained from three different sets of absolute cross-section measurements. The associated activity technique was applied in the 450- to 650-keV range, the black neutron detector was used for absolute flux measurements at 800 keV and 3.5 MeV, and a calibrated vanadium bath was used at 500 keV. The results from the present measurements agree well with more recent data obtained by other experimenters but differ up to a factor of 2 from older values.

Key concepts: Nuclear physics, Neutron cross section, Neutron, Neutron flux, Range (aeronautics), Physics, Fission, Cross section (physics)

Related papers

Back to paper searchBrowse research topicsOriginal source
Relative and Absolute Measurements of the Fast-Neutron Fission Cross Section of Uranium-235 — Research Paper | ScholarLens