Assessment of Wrist Function After Simulated Total Wrist Arthrodesis
Richard M. Hinds, Eitan Melamed, April O’Connell, Francoise Cherry, Monica Seu, John T. Capo
Abstract
Richard M. Hinds, Eitan Melamed, April O’Connell, Francoise Cherry, Monica Seu, John T. Capo
Abstract
Background: There is poor consensus in the literature regarding associated functional limitation and the preferred wrist position for total wrist arthrodesis. The purpose of the current investigation was twofold: (1) to assess the functional limitations of wrist arthrodesis and (2) to determine the optimal position for wrist arthrodesis using a simulated wrist fusion model. Methods: Twenty healthy volunteers underwent simulated wrist arthrodesis in 6 different positions using custom-molded wrist splints: 15° extension with 0° radio-ulnar deviation, 15° extension with 10° ulnar deviation, 15° extension with 10° radial deviation, 0° extension with 0° radio-ulnar deviation, 0° extension with 10° ulnar deviation, and 0° extension with 10° radial deviation. Each volunteer was independently assessed for wrist function using the Jebsen-Taylor hand function test, grip strength, and satisfaction in the simulated wrist fusion positions. Comparisons between all simulated fusion wrists and the baseline unsplinted wrist as well as among the 6 simulated fusion positions were performed. Results: Turning over a card (5.1 vs 4.3 seconds), picking up small objects (7.1 vs 5.8 seconds), and simulated feeding (8.3 vs 7.1 seconds) as well as total Jebsen-Taylor test duration (41.8 vs 37.9 seconds) was significantly longer in simulated fusion wrists. Both grip strength (55.9 vs 80.7 kg) and satisfaction scores (6.4 vs 9.6) were lower in simulated fusion wrists. Wrists in 0° extension also demonstrated significantly shorter durations in stacking checkers than wrists in 15° extension. Conclusion: Our findings suggest that wrist arthrodesis may only compromise select wrist functions. Among the tested wrist fusion positions, wrists fused in neutral may demonstrate better function than wrist fused in slight extension. However, grip strength and satisfaction seem to be unaffected by wrist fusion position.
OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Background: There is poor consensus in the literature regarding associated functional limitation and the preferred wrist position for total wrist arthrodesis. The purpose of the current investigation was twofold: (1) to assess the functional limitations of wrist arthrodesis and (2) to determine the optimal position for wrist arthrodesis using a simulated wrist fusion model. Methods: Twenty healthy volunteers underwent simulated wrist arthrodesis in 6 different positions using custom-molded wrist splints: 15° extension with 0° radio-ulnar deviation, 15° extension with 10° ulnar deviation, 15° extension with 10° radial deviation, 0° extension with 0° radio-ulnar deviation, 0° extension with 10° ulnar deviation, and 0° extension with 10° radial deviation. Each volunteer was independently assessed for wrist function using the Jebsen-Taylor hand function test, grip strength, and satisfaction in the simulated wrist fusion positions. Comparisons between all simulated fusion wrists and the baseline unsplinted wrist as well as among the 6 simulated fusion positions were performed. Results: Turning over a card (5.1 vs 4.3 seconds), picking up small objects (7.1 vs 5.8 seconds), and simulated feeding (8.3 vs 7.1 seconds) as well as total Jebsen-Taylor test duration (41.8 vs 37.9 seconds) was significantly longer in simulated fusion wrists. Both grip strength (55.9 vs 80.7 kg) and satisfaction scores (6.4 vs 9.6) were lower in simulated fusion wrists. Wrists in 0° extension also demonstrated significantly shorter durations in stacking checkers than wrists in 15° extension. Conclusion: Our findings suggest that wrist arthrodesis may only compromise select wrist functions. Among the tested wrist fusion positions, wrists fused in neutral may demonstrate better function than wrist fused in slight extension. However, grip strength and satisfaction seem to be unaffected by wrist fusion position.
Key concepts: Wrist, Ulnar deviation, Medicine, Arthrodesis, Grip strength, Orthodontics, Physical therapy, Surgery