2016Indian Heart JournalOpen access

Veno-venous loop through coronary sinus for LV lead placement during cardiac resynchronization therapy

Ranjit Kumar Nath, Ajay Raj, C. Parvatagouda, Neeraj Pandit

Open full text 5 citations

Abstract

Left ventricular lead placement in the appropriate branch of coronary sinus is the key to successful cardiac resynchronization therapy (CRT) and this step is technically challenging. We describe a case of non-ischemic cardiomyopathy with heart failure, taken up for cardiac resynchronization therapy with defibrillator (CRT-D) implantation. The quadripolar left ventricular lead was impossible to advance into the target lateral branch of the coronary sinus. We made a veno-venous loop, advancing the coronary guidewire through the middle cardiac vein to coronary sinus and then to superior vena cava. The guidewire then snared through the same left subclavian vein and exteriorized. Over this loop, the left ventricular lead of the CRT-D device was implanted successfully. This novel approach can be used to successfully implant the LV lead in difficult to implant situations, obviating the need for thoracotomy or other methods of LV lead implantation.

Open-access reader

About this research paper

What this paper is about

Left ventricular lead placement in the appropriate branch of coronary sinus is the key to successful cardiac resynchronization therapy (CRT) and this step is technically challenging. We describe a case of non-ischemic cardiomyopathy with heart failure, taken up for cardiac resynchronization therapy with defibrillator (CRT-D) implantation. The quadripolar left ventricular lead was impossible to advance into the target lateral branch of the coronary sinus. We made a veno-venous loop, advancing the coronary guidewire through the middle cardiac vein to coronary sinus and then to superior vena cava. The guidewire then snared through the same left subclavian vein and exteriorized. Over this loop, the left ventricular lead of the CRT-D device was implanted successfully. This novel approach can be used to successfully implant the LV lead in difficult to implant situations, obviating the need for thoracotomy or other methods of LV lead implantation.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Left ventricular lead placement in the appropriate branch of coronary sinus is the key to successful cardiac resynchronization therapy (CRT) and this step is technically challenging. We describe a case of non-ischemic cardiomyopathy with heart failure, taken up for cardiac resynchronization therapy with defibrillator (CRT-D) implantation. The quadripolar left ventricular lead was impossible to advance into the target lateral branch of the coronary sinus. We made a veno-venous loop, advancing the coronary guidewire through the middle cardiac vein to coronary sinus and then to superior vena cava. The guidewire then snared through the same left subclavian vein and exteriorized. Over this loop, the left ventricular lead of the CRT-D device was implanted successfully. This novel approach can be used to successfully implant the LV lead in difficult to implant situations, obviating the need for thoracotomy or other methods of LV lead implantation.

Key concepts: Cardiac resynchronization therapy, Medicine, Coronary sinus, Cardiology, Coronary Vein, Internal medicine, Implant, Heart failure

Related papers

Back to paper searchBrowse research topicsOriginal source
Veno-venous loop through coronary sinus for LV lead placement during cardiac resynchronization therapy — Research Paper | ScholarLens