2000•PubMedRequires access

Scanning laser polarimetry in evaluation of retinal nerve fiber layer thickness for normal Taiwanese.

Hong-Jeng Chen, Yang-Ming Lee, Lin‐Chung Woung, Jieh‐Ren Jou, Hwi-Ju Lin

Open publisher page 0 citations

Abstract

Scanning laser polarimetry has been used recently for the measurement of retinal nerve fiber layer (RNFL) thickness, taking advantage of the birefrigence of the RNFL. We observe the RNFL with the instrument and try to find out a set of normal basic values of the RNFL thickness for clinical comparison. One hundred normal volunteers of different age groups were recruited for this study. There are 44 males and 56 females with a mean (1SD) age of 36.17(14.77) years. Three consecutive 15-degree polarimetric maps were acquired for each subject. RNFL thickness measurements were obtained at 1.75 disc diameters ring from the optic nerve. Four 90-degree quadrants were identified. As a result, the average of RNFL thickness is 90.69 (20.20) microns in the superior quadrant, 80.45 (17.4) microns in the inferior quadrant, 59.28 (15.37) microns in the nasal quadrant, and 48.98 (15.72) microns in the temporal quadrant with a mean thickness value of 69.86 (13.97) microns. Superior and inferior quadrants showed a comparatively thicker nerve fiber layer than nasal and temporal quadrants. The temporal quadrant was always the lowest. The axial length does not affect the RNFL thickness and no significant difference between males and females exists. However, an obvious inverse linear correlation between age and the RNFL thickness in all quadrants is found. The average RNFL thickness decreased with age by 0.26 micron per year. (R2 = 0.081, p-value = 0.004). When compared with the normal range, age-match would be necessary.

About this research paper

What this paper is about

Scanning laser polarimetry has been used recently for the measurement of retinal nerve fiber layer (RNFL) thickness, taking advantage of the birefrigence of the RNFL. We observe the RNFL with the instrument and try to find out a set of normal basic values of the RNFL thickness for clinical comparison. One hundred normal volunteers of different age groups were recruited for this study. There are 44 males and 56 females with a mean (1SD) age of 36.17(14.77) years. Three consecutive 15-degree polarimetric maps were acquired for each subject. RNFL thickness measurements were obtained at 1.75 disc diameters ring from the optic nerve. Four 90-degree quadrants were identified. As a result, the average of RNFL thickness is 90.69 (20.20) microns in the superior quadrant, 80.45 (17.4) microns in the inferior quadrant, 59.28 (15.37) microns in the nasal quadrant, and 48.98 (15.72) microns in the temporal quadrant with a mean thickness value of 69.86 (13.97) microns. Superior and inferior quadrants showed a comparatively thicker nerve fiber layer than nasal and temporal quadrants. The temporal quadrant was always the lowest. The axial length does not affect the RNFL thickness and no significant difference between males and females exists. However, an obvious inverse linear correlation between age and the RNFL thickness in all quadrants is found. The average RNFL thickness decreased with age by 0.26 micron per year. (R2 = 0.081, p-value = 0.004). When compared with the normal range, age-match would be necessary.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Scanning laser polarimetry has been used recently for the measurement of retinal nerve fiber layer (RNFL) thickness, taking advantage of the birefrigence of the RNFL. We observe the RNFL with the instrument and try to find out a set of normal basic values of the RNFL thickness for clinical comparison. One hundred normal volunteers of different age groups were recruited for this study. There are 44 males and 56 females with a mean (1SD) age of 36.17(14.77) years. Three consecutive 15-degree polarimetric maps were acquired for each subject. RNFL thickness measurements were obtained at 1.75 disc diameters ring from the optic nerve. Four 90-degree quadrants were identified. As a result, the average of RNFL thickness is 90.69 (20.20) microns in the superior quadrant, 80.45 (17.4) microns in the inferior quadrant, 59.28 (15.37) microns in the nasal quadrant, and 48.98 (15.72) microns in the temporal quadrant with a mean thickness value of 69.86 (13.97) microns. Superior and inferior quadrants showed a comparatively thicker nerve fiber layer than nasal and temporal quadrants. The temporal quadrant was always the lowest. The axial length does not affect the RNFL thickness and no significant difference between males and females exists. However, an obvious inverse linear correlation between age and the RNFL thickness in all quadrants is found. The average RNFL thickness decreased with age by 0.26 micron per year. (R2 = 0.081, p-value = 0.004). When compared with the normal range, age-match would be necessary.

Key concepts: Quadrant (abdomen), Medicine, Nerve fiber layer, Retinal, Scanning laser polarimetry, Ophthalmology, Nerve fiber, Anatomy

Related papers

Back to paper searchBrowse research topicsOriginal source
Scanning laser polarimetry in evaluation of retinal nerve fiber layer thickness for normal Taiwanese. — Research Paper | ScholarLens