2011cIRcle (University of British Columbia)Open access

The efficiency of scintillation counters for gamma ray detection

John Laurence Leigh

Open full text 0 citations

Abstract

The efficiency of NaI(T1) scintillation counters for the detection of gamma rays is discussed and experimentally determined. Experimental efficiencies, based upon the number of counts above a bias equal to one-half the gamma ray energy and a solid angle defined to the crystal effective centre, for a three-inch-diameter by three-inch long (3 x 3) crystal are given for gamma ray energies of 0.51, 1.275 and 6.14 MeV. Gamma ray spectra at 1.275 and 6.14 MeV are extrapolated to zero energy in order to compare theoretical efficiencies, based upon the integrated primary absorption, with the experimental results. These results show that, with experience, one can expect accuracy to better than 5% at these energies. Tables are given of the theoretical efficiency for 3x3, 2¾ x 4½ and 5x4 crystals for several gamma ray energies and source-to-counter distances of from 0.1 cm to 1 m.

About this research paper

What this paper is about

The efficiency of NaI(T1) scintillation counters for the detection of gamma rays is discussed and experimentally determined. Experimental efficiencies, based upon the number of counts above a bias equal to one-half the gamma ray energy and a solid angle defined to the crystal effective centre, for a three-inch-diameter by three-inch long (3 x 3) crystal are given for gamma ray energies of 0.51, 1.275 and 6.14 MeV. Gamma ray spectra at 1.275 and 6.14 MeV are extrapolated to zero energy in order to compare theoretical efficiencies, based upon the integrated primary absorption, with the experimental results. These results show that, with experience, one can expect accuracy to better than 5% at these energies. Tables are given of the theoretical efficiency for 3x3, 2¾ x 4½ and 5x4 crystals for several gamma ray energies and source-to-counter distances of from 0.1 cm to 1 m.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The efficiency of NaI(T1) scintillation counters for the detection of gamma rays is discussed and experimentally determined. Experimental efficiencies, based upon the number of counts above a bias equal to one-half the gamma ray energy and a solid angle defined to the crystal effective centre, for a three-inch-diameter by three-inch long (3 x 3) crystal are given for gamma ray energies of 0.51, 1.275 and 6.14 MeV. Gamma ray spectra at 1.275 and 6.14 MeV are extrapolated to zero energy in order to compare theoretical efficiencies, based upon the integrated primary absorption, with the experimental results. These results show that, with experience, one can expect accuracy to better than 5% at these energies. Tables are given of the theoretical efficiency for 3x3, 2¾ x 4½ and 5x4 crystals for several gamma ray energies and source-to-counter distances of from 0.1 cm to 1 m.

Key concepts: Scintillation counter, Gamma ray, Scintillation, Physics, Computer science, Detector, Optics, Nuclear physics

Related papers

Back to paper searchBrowse research topicsOriginal source
The efficiency of scintillation counters for gamma ray detection — Research Paper | ScholarLens