2015•IEEE Transactions on Plasma ScienceRequires access

Experimental Investigations Into Pulse-Charged Spark Gap Recovery Times and Influencing Factors

Chandra Sekhar Reddy, Archana Sharma, Kailash Chandra Mittal

Open publisher page 23 citations

Abstract

The spark gap switch is the key element in any pulsed power system, which directly determines the pulse repetitive frequency of the system. The dielectric recovery data of the spark gap play a basic role, but they have not yet been adequately studied for repetitive pulse charge conditions. This paper describes some of the factors that affect the recovery of spark gap switch for pulse-charged operation. A two-pulse technique has been used, in which the first pulse is applied to the spark gap to overvolt the gap and initiate the breakdown and the second pulse is used to determine the recovery voltage of the gap. The effects of electrode size, pulse rise time, and conduction current on the spark gap recovery performance are presented. Experiments were performed by using a double-pulse generator capable of generating 40-kV pulses with a delay of 1 ms-1 s. Spark gap electrodes of 34-, 40-, and 68-mm diameters and a point type were used in the study. The effect of voltage rise rate was studied by changing the charging capacitor to 100, 500, and 1000 nF in the circuit. An intermediate plateau was observed in the spark gap recovery curves. In addition, an increase in the output impedance resulted in a decrease in the time taken for the recovery of the spark gap. Also, the switch recovery appears to be largely dependent on the electrode shape and size compared with the pulse rise time.

About this research paper

What this paper is about

The spark gap switch is the key element in any pulsed power system, which directly determines the pulse repetitive frequency of the system. The dielectric recovery data of the spark gap play a basic role, but they have not yet been adequately studied for repetitive pulse charge conditions. This paper describes some of the factors that affect the recovery of spark gap switch for pulse-charged operation. A two-pulse technique has been used, in which the first pulse is applied to the spark gap to overvolt the gap and initiate the breakdown and the second pulse is used to determine the recovery voltage of the gap. The effects of electrode size, pulse rise time, and conduction current on the spark gap recovery performance are presented. Experiments were performed by using a double-pulse generator capable of generating 40-kV pulses with a delay of 1 ms-1 s. Spark gap electrodes of 34-, 40-, and 68-mm diameters and a point type were used in the study. The effect of voltage rise rate was studied by changing the charging capacitor to 100, 500, and 1000 nF in the circuit. An intermediate plateau was observed in the spark gap recovery curves. In addition, an increase in the output impedance resulted in a decrease in the time taken for the recovery of the spark gap. Also, the switch recovery appears to be largely dependent on the electrode shape and size compared with the pulse rise time.

Why it matters

OpenAlex reports 23 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The spark gap switch is the key element in any pulsed power system, which directly determines the pulse repetitive frequency of the system. The dielectric recovery data of the spark gap play a basic role, but they have not yet been adequately studied for repetitive pulse charge conditions. This paper describes some of the factors that affect the recovery of spark gap switch for pulse-charged operation. A two-pulse technique has been used, in which the first pulse is applied to the spark gap to overvolt the gap and initiate the breakdown and the second pulse is used to determine the recovery voltage of the gap. The effects of electrode size, pulse rise time, and conduction current on the spark gap recovery performance are presented. Experiments were performed by using a double-pulse generator capable of generating 40-kV pulses with a delay of 1 ms-1 s. Spark gap electrodes of 34-, 40-, and 68-mm diameters and a point type were used in the study. The effect of voltage rise rate was studied by changing the charging capacitor to 100, 500, and 1000 nF in the circuit. An intermediate plateau was observed in the spark gap recovery curves. In addition, an increase in the output impedance resulted in a decrease in the time taken for the recovery of the spark gap. Also, the switch recovery appears to be largely dependent on the electrode shape and size compared with the pulse rise time.

Key concepts: Spark gap, Materials science, Pulse (music), Pulse generator, Electrode, Rise time, Marx generator, Capacitor

Related papers

Back to paper searchBrowse research topicsOriginal source
Experimental Investigations Into Pulse-Charged Spark Gap Recovery Times and Influencing Factors — Research Paper | ScholarLens