2015IEEE Transactions on Biomedical Circuits and SystemsRequires access

A Low-Power Gateable Vernier Ring Oscillator Time-to-Digital Converter for Biomedical Imaging Applications

Cheng Zeng, M. Jamal Deen, Hao Peng

Open publisher page 85 citations

Abstract

In this paper, a high resolution, high precision and ultra-low power consumption time-to-digital converter (TDC) is presented. The proposed TDC is based on the gateable Vernier ring oscillator architecture. Fine resolution is achieved through two ring oscillators arranged in the Vernier configuration. This TDC employs a single-transition end-of-conversion detection circuit and turns off the ring oscillators whenever the conversion is completed to reduce power consumption. The prototype chip is fabricated in a standard 130 nm digital CMOS process and its area is only 0.03 mm(2). Using a 1.2 V supply, the TDC achieves a resolution of 7.3 ps, a single-shot precision of 1.0LSB, and an average power consumption of 1.2 mW. A root-mean-square integral nonlinearity (INL) of 1.2 LSB is obtained with the help of an INL look-up-table calibration. Compared to previously reported ring-oscillator based TDCs, the proposed design achieves the lowest power consumption to date.

About this research paper

What this paper is about

In this paper, a high resolution, high precision and ultra-low power consumption time-to-digital converter (TDC) is presented. The proposed TDC is based on the gateable Vernier ring oscillator architecture. Fine resolution is achieved through two ring oscillators arranged in the Vernier configuration. This TDC employs a single-transition end-of-conversion detection circuit and turns off the ring oscillators whenever the conversion is completed to reduce power consumption. The prototype chip is fabricated in a standard 130 nm digital CMOS process and its area is only 0.03 mm(2). Using a 1.2 V supply, the TDC achieves a resolution of 7.3 ps, a single-shot precision of 1.0LSB, and an average power consumption of 1.2 mW. A root-mean-square integral nonlinearity (INL) of 1.2 LSB is obtained with the help of an INL look-up-table calibration. Compared to previously reported ring-oscillator based TDCs, the proposed design achieves the lowest power consumption to date.

Why it matters

OpenAlex reports 85 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this paper, a high resolution, high precision and ultra-low power consumption time-to-digital converter (TDC) is presented. The proposed TDC is based on the gateable Vernier ring oscillator architecture. Fine resolution is achieved through two ring oscillators arranged in the Vernier configuration. This TDC employs a single-transition end-of-conversion detection circuit and turns off the ring oscillators whenever the conversion is completed to reduce power consumption. The prototype chip is fabricated in a standard 130 nm digital CMOS process and its area is only 0.03 mm(2). Using a 1.2 V supply, the TDC achieves a resolution of 7.3 ps, a single-shot precision of 1.0LSB, and an average power consumption of 1.2 mW. A root-mean-square integral nonlinearity (INL) of 1.2 LSB is obtained with the help of an INL look-up-table calibration. Compared to previously reported ring-oscillator based TDCs, the proposed design achieves the lowest power consumption to date.

Key concepts: Vernier scale, Ring oscillator, Integral nonlinearity, Time-to-digital converter, Differential nonlinearity, Ring (chemistry), CMOS, Chip

Related papers

Back to paper searchBrowse research topicsOriginal source
A Low-Power Gateable Vernier Ring Oscillator Time-to-Digital Converter for Biomedical Imaging Applications — Research Paper | ScholarLens