2016•Journal of Applied Pharmaceutical ScienceOpen access

Development and Validation of a Stability Indicating HPLC Method for the Simultaneous Analysis of Esomeprazole and Itopride in Bulk and In Capsules

M. V. Basaweswara Rao, Kulshrestha Mayank Krishna, B. Hari Babu

Open full text 5 citations

Abstract

A rapid, simple, selective, precise, and accurate stability indicating HPLC method has been developed and validated for the simultaneous analysis of esomeprazole and itopride in bulk and in capsule form.An isocratic separation was achieved using a Hypersil C4 (250 x 4.6 mm), 5 μm particle size column with a flow rate of 1 mL/min and photodiode array detector at 272 nm.The mobile phase consisted of 0.1M dipotassium hydrogen phosphate: acetonitrile (40:60 v/v).The method was validated for selectivity, specificity, linearity, precision, accuracy and robustness.The selectivity of the method was determined by assessing interference from the placebo, components of mobile phase and common excipients in pharmaceutical formulations.Whereas, specificity was established by stress degradation studies.The method was linear over the concentration range 40 -120 μg/mL (R 2 = 0.9999) and 150-450 μg/mL (R 2 = 0.9999) for esomeprazole and itopride, respectively.Limit of detection is 0.207 and 0.724 μg/mL & Limit of quantitation is 0.691 and 2.415 μg/mL for esomeprazole and itopride, respectively.The precision and accuracy of the method was found to be acceptable.The method was found to be robust and suitable for the simultaneous analysis of esomeprazole and itopride in a capsule formulation.Degradation products resulting from the stress studies did not interfere with the detection and quantification of esomeprazole and itopride.The proposed HPLC method is thus stability-indicating.

Open-access reader

About this research paper

What this paper is about

A rapid, simple, selective, precise, and accurate stability indicating HPLC method has been developed and validated for the simultaneous analysis of esomeprazole and itopride in bulk and in capsule form.An isocratic separation was achieved using a Hypersil C4 (250 x 4.6 mm), 5 μm particle size column with a flow rate of 1 mL/min and photodiode array detector at 272 nm.The mobile phase consisted of 0.1M dipotassium hydrogen phosphate: acetonitrile (40:60 v/v).The method was validated for selectivity, specificity, linearity, precision, accuracy and robustness.The selectivity of the method was determined by assessing interference from the placebo, components of mobile phase and common excipients in pharmaceutical formulations.Whereas, specificity was established by stress degradation studies.The method was linear over the concentration range 40 -120 μg/mL (R 2 = 0.9999) and 150-450 μg/mL (R 2 = 0.9999) for esomeprazole and itopride, respectively.Limit of detection is 0.207 and 0.724 μg/mL & Limit of quantitation is 0.691 and 2.415 μg/mL for esomeprazole and itopride, respectively.The precision and accuracy of the method was found to be acceptable.The method was found to be robust and suitable for the simultaneous analysis of esomeprazole and itopride in a capsule formulation.Degradation products resulting from the stress studies did not interfere with the detection and quantification of esomeprazole and itopride.The proposed HPLC method is thus stability-indicating.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A rapid, simple, selective, precise, and accurate stability indicating HPLC method has been developed and validated for the simultaneous analysis of esomeprazole and itopride in bulk and in capsule form.An isocratic separation was achieved using a Hypersil C4 (250 x 4.6 mm), 5 μm particle size column with a flow rate of 1 mL/min and photodiode array detector at 272 nm.The mobile phase consisted of 0.1M dipotassium hydrogen phosphate: acetonitrile (40:60 v/v).The method was validated for selectivity, specificity, linearity, precision, accuracy and robustness.The selectivity of the method was determined by assessing interference from the placebo, components of mobile phase and common excipients in pharmaceutical formulations.Whereas, specificity was established by stress degradation studies.The method was linear over the concentration range 40 -120 μg/mL (R 2 = 0.9999) and 150-450 μg/mL (R 2 = 0.9999) for esomeprazole and itopride, respectively.Limit of detection is 0.207 and 0.724 μg/mL & Limit of quantitation is 0.691 and 2.415 μg/mL for esomeprazole and itopride, respectively.The precision and accuracy of the method was found to be acceptable.The method was found to be robust and suitable for the simultaneous analysis of esomeprazole and itopride in a capsule formulation.Degradation products resulting from the stress studies did not interfere with the detection and quantification of esomeprazole and itopride.The proposed HPLC method is thus stability-indicating.

Key concepts: Esomeprazole, Chromatography, Stability (learning theory), Chemistry, Mathematics, Computer science, Internal medicine, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Development and Validation of a Stability Indicating HPLC Method for the Simultaneous Analysis of Esomeprazole and Itopride in Bulk and In Capsules — Research Paper | ScholarLens