A Validated Reversed Phase HPLC-Method for the Determination of Aceclofenac and Tizanidine in Tablets
S. Nelson Kumar, Senthil Senthil, Kumar Nallasivan Sam Solomon, Venkatnarayanan
Abstract
S. Nelson Kumar, Senthil Senthil, Kumar Nallasivan Sam Solomon, Venkatnarayanan
Abstract
A new simple, accurate, precise and reproducible Reverse Phase-High Performance Liquid Chromatographic method has been developed for the simultaneous estimation of Aceclofenac and Tizanidine in tablet dosage forms using C18 column (Ineretsil, 250 x 4.6 mm, 5 μm) in isocratic mode. The mobile phase consisted of acetonitrile, methanol and 20 mM phosphate buffer adjusted to pH 3.5 in ratio of (40:30:30 v/v) with Ultraviolet-Visible detection at 230 nm. The method was linear over the concentration range for aceclofenac120-280 μg/ml and for tizanidine 2-40 μg/ml. The recoveries of Tizanidine and Aceclofenac were found to be in the range of 99.45-100.61% and 99.56-101.32% respectively. The validation of method was carried out using International Conference on Harmonization-guidelines. The described High Performance Liquid Chromatographic method was successfully employed for the analysis of pharmaceutical formulations containing combined dosage form.
OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A new simple, accurate, precise and reproducible Reverse Phase-High Performance Liquid Chromatographic method has been developed for the simultaneous estimation of Aceclofenac and Tizanidine in tablet dosage forms using C18 column (Ineretsil, 250 x 4.6 mm, 5 μm) in isocratic mode. The mobile phase consisted of acetonitrile, methanol and 20 mM phosphate buffer adjusted to pH 3.5 in ratio of (40:30:30 v/v) with Ultraviolet-Visible detection at 230 nm. The method was linear over the concentration range for aceclofenac120-280 μg/ml and for tizanidine 2-40 μg/ml. The recoveries of Tizanidine and Aceclofenac were found to be in the range of 99.45-100.61% and 99.56-101.32% respectively. The validation of method was carried out using International Conference on Harmonization-guidelines. The described High Performance Liquid Chromatographic method was successfully employed for the analysis of pharmaceutical formulations containing combined dosage form.
Key concepts: Tizanidine, Aceclofenac, Chromatography, Dosage form, Chemistry, High-performance liquid chromatography, Phosphate buffered saline, Acetonitrile