1964Journal of the Japan Institute of Metals and MaterialsOpen access

Method for the Determinations of Niobium and Tantalum in Titanium Alloys and Zirconium-Base Alloys

Toshio Sawada, Sakae Kato

Open full text 1 citations

Abstract

A method for the anion-exchange separation and gravimetric determination of niobium and tantalum in titanium alloys and zirconium-base alloys has been developed. Niobium up to 40 mg, and tantalum up to 60 mg in 6N hydrofluoric-4N hydrochloric acid solution containing a maximum of 2.5 g of titanium or zirconium ion per 50 mL, can be quantitatively adsorbed on a 35-cm column prepared from 25 mL (swelling volume in water) of the strong-base anion-exchange resin Dowex 1-X4(F, Cl) at the flow rate from 3 to 4 mL per square cm per minute. After washing the column, niobium cotaining no tantalum can be eluted with 200 mL of 3M ammonium chloride-1N hydrofluoric acid solution (A), and tantalum containing no niobium with 200 mL of 3M ammonium chloride-1M ammonium fluoride solution. For a mixture of niobium and tantalum, niobium can be separately eluted with 200 mL of 2.3N hydrofluoric-3.0N hydrochloric acid solution (B). The eluate (A) containing niobium is neutralized with ammonium hydroxide solution. Then niobium, and tantalum in the eluate are precipitated with cupferron at the temperature below 10°C after adjusting the acidity to 1∼2N by the addition of 8 g of boric acid and sufficient hydrochloric acid. Niobium in the eluate (B) is also precipitated quantitatively from 2∼3N hydrochloric acid solution with cupferron after the addition of 40 mL of ammonium hydroxide solution and 15 g of boric acid. The precipitates are filterd, washed, ignited at 1000°C for an hour, and weighed as Nb2O5 and Ta2O5 respectively. Nitric acid may be present up to 3N under the conditions of the adsorption. All elements normally found in titanium alloys and zirconium-base alloys cause no interference under the developed conditions. Amounts of 0.1∼30 percent niobium, and 0.1∼5 percent tantalum in titanium alloys and zirconium-base alloys are determined by a developed method, the results of which show moderate precision and satisfaction.

Open-access reader

About this research paper

What this paper is about

A method for the anion-exchange separation and gravimetric determination of niobium and tantalum in titanium alloys and zirconium-base alloys has been developed. Niobium up to 40 mg, and tantalum up to 60 mg in 6N hydrofluoric-4N hydrochloric acid solution containing a maximum of 2.5 g of titanium or zirconium ion per 50 mL, can be quantitatively adsorbed on a 35-cm column prepared from 25 mL (swelling volume in water) of the strong-base anion-exchange resin Dowex 1-X4(F, Cl) at the flow rate from 3 to 4 mL per square cm per minute. After washing the column, niobium cotaining no tantalum can be eluted with 200 mL of 3M ammonium chloride-1N hydrofluoric acid solution (A), and tantalum containing no niobium with 200 mL of 3M ammonium chloride-1M ammonium fluoride solution. For a mixture of niobium and tantalum, niobium can be separately eluted with 200 mL of 2.3N hydrofluoric-3.0N hydrochloric acid solution (B). The eluate (A) containing niobium is neutralized with ammonium hydroxide solution. Then niobium, and tantalum in the eluate are precipitated with cupferron at the temperature below 10°C after adjusting the acidity to 1∼2N by the addition of 8 g of boric acid and sufficient hydrochloric acid. Niobium in the eluate (B) is also precipitated quantitatively from 2∼3N hydrochloric acid solution with cupferron after the addition of 40 mL of ammonium hydroxide solution and 15 g of boric acid. The precipitates are filterd, washed, ignited at 1000°C for an hour, and weighed as Nb2O5 and Ta2O5 respectively. Nitric acid may be present up to 3N under the conditions of the adsorption. All elements normally found in titanium alloys and zirconium-base alloys cause no interference under the developed conditions. Amounts of 0.1∼30 percent niobium, and 0.1∼5 percent tantalum in titanium alloys and zirconium-base alloys are determined by a developed method, the results of which show moderate precision and satisfaction.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method for the anion-exchange separation and gravimetric determination of niobium and tantalum in titanium alloys and zirconium-base alloys has been developed. Niobium up to 40 mg, and tantalum up to 60 mg in 6N hydrofluoric-4N hydrochloric acid solution containing a maximum of 2.5 g of titanium or zirconium ion per 50 mL, can be quantitatively adsorbed on a 35-cm column prepared from 25 mL (swelling volume in water) of the strong-base anion-exchange resin Dowex 1-X4(F, Cl) at the flow rate from 3 to 4 mL per square cm per minute. After washing the column, niobium cotaining no tantalum can be eluted with 200 mL of 3M ammonium chloride-1N hydrofluoric acid solution (A), and tantalum containing no niobium with 200 mL of 3M ammonium chloride-1M ammonium fluoride solution. For a mixture of niobium and tantalum, niobium can be separately eluted with 200 mL of 2.3N hydrofluoric-3.0N hydrochloric acid solution (B). The eluate (A) containing niobium is neutralized with ammonium hydroxide solution. Then niobium, and tantalum in the eluate are precipitated with cupferron at the temperature below 10°C after adjusting the acidity to 1∼2N by the addition of 8 g of boric acid and sufficient hydrochloric acid. Niobium in the eluate (B) is also precipitated quantitatively from 2∼3N hydrochloric acid solution with cupferron after the addition of 40 mL of ammonium hydroxide solution and 15 g of boric acid. The precipitates are filterd, washed, ignited at 1000°C for an hour, and weighed as Nb2O5 and Ta2O5 respectively. Nitric acid may be present up to 3N under the conditions of the adsorption. All elements normally found in titanium alloys and zirconium-base alloys cause no interference under the developed conditions. Amounts of 0.1∼30 percent niobium, and 0.1∼5 percent tantalum in titanium alloys and zirconium-base alloys are determined by a developed method, the results of which show moderate precision and satisfaction.

Key concepts: Tantalum, Hydrochloric acid, Hydrofluoric acid, Niobium, Inorganic chemistry, Zirconium, Ammonium hydroxide, Boric acid

Related papers

Back to paper searchBrowse research topicsOriginal source
Method for the Determinations of Niobium and Tantalum in Titanium Alloys and Zirconium-Base Alloys — Research Paper | ScholarLens