2014대한설비공학회 2014년도 하계학술발표대회Requires access

에너지절감을 위한 Free Cooling System의 성능 특성

윤정인, 손창효, 허정호, 김영민

Open publisher page 0 citations

Abstract

As the facilty which has cooling load at all times has increased, using the free-cooling system is increasing. The free cooling system is able to drop room temperature by cooling water heat exchanged outdoor air. In this study, the performance characteristics of free cooling system is analyzed and compared energy consumption of free cooling system with existing system's. The main result is as follows. In case that the temperature of outdoor air is under 2℃, It is able to handle cooling load by operating dry-cooler solely. But cooling system should be operated when the temperature of outdoor air is over 2℃. The effectiveness of free cooling system appeared between November and March. Comparing free cooling system with existing system, energy can be saved about 15% annually. It is resonable to apply the free cooling system to the facilities having cooling load constantly.

About this research paper

What this paper is about

As the facilty which has cooling load at all times has increased, using the free-cooling system is increasing. The free cooling system is able to drop room temperature by cooling water heat exchanged outdoor air. In this study, the performance characteristics of free cooling system is analyzed and compared energy consumption of free cooling system with existing system's. The main result is as follows. In case that the temperature of outdoor air is under 2℃, It is able to handle cooling load by operating dry-cooler solely. But cooling system should be operated when the temperature of outdoor air is over 2℃. The effectiveness of free cooling system appeared between November and March. Comparing free cooling system with existing system, energy can be saved about 15% annually. It is resonable to apply the free cooling system to the facilities having cooling load constantly.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

As the facilty which has cooling load at all times has increased, using the free-cooling system is increasing. The free cooling system is able to drop room temperature by cooling water heat exchanged outdoor air. In this study, the performance characteristics of free cooling system is analyzed and compared energy consumption of free cooling system with existing system's. The main result is as follows. In case that the temperature of outdoor air is under 2℃, It is able to handle cooling load by operating dry-cooler solely. But cooling system should be operated when the temperature of outdoor air is over 2℃. The effectiveness of free cooling system appeared between November and March. Comparing free cooling system with existing system, energy can be saved about 15% annually. It is resonable to apply the free cooling system to the facilities having cooling load constantly.

Key concepts: Free cooling, Water cooling, Active cooling, Cooling load, Air cooling, Environmental science, Passive cooling, Evaporative cooler