2005PubMedRequires access

A simple ice nucleation spectrometer.

David A. Wharton, Jodi S. Mutch, Peter W. Wilson, C. J. Marshall, Miang Lim

Open publisher page 18 citations

Abstract

The construction of a simple ice nucleation spectrometer is described. It uses 10 microliter droplets loaded into glass capillary tubes which are then inserted into an aluminium holder. Each holder takes six capillary tubes surrounding a central thermocouple. Four holders are placed into a cooling block, cooled by fluid from a programmable refrigerated circulator, and the thermocouples interfaced to a computer to record temperatures. Freezing of each sample is detected by an exotherm on the temperature recording, with 24 samples recorded per run. The spectrometer was tested using deionized water, an extract from a New Zealand alpine cockroach and an extract of lawn grass. The cockroach extract is estimated to contain about 10(3) more nucleators, active at -5 degrees C, than the grass extract.

About this research paper

What this paper is about

The construction of a simple ice nucleation spectrometer is described. It uses 10 microliter droplets loaded into glass capillary tubes which are then inserted into an aluminium holder. Each holder takes six capillary tubes surrounding a central thermocouple. Four holders are placed into a cooling block, cooled by fluid from a programmable refrigerated circulator, and the thermocouples interfaced to a computer to record temperatures. Freezing of each sample is detected by an exotherm on the temperature recording, with 24 samples recorded per run. The spectrometer was tested using deionized water, an extract from a New Zealand alpine cockroach and an extract of lawn grass. The cockroach extract is estimated to contain about 10(3) more nucleators, active at -5 degrees C, than the grass extract.

Why it matters

OpenAlex reports 18 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The construction of a simple ice nucleation spectrometer is described. It uses 10 microliter droplets loaded into glass capillary tubes which are then inserted into an aluminium holder. Each holder takes six capillary tubes surrounding a central thermocouple. Four holders are placed into a cooling block, cooled by fluid from a programmable refrigerated circulator, and the thermocouples interfaced to a computer to record temperatures. Freezing of each sample is detected by an exotherm on the temperature recording, with 24 samples recorded per run. The spectrometer was tested using deionized water, an extract from a New Zealand alpine cockroach and an extract of lawn grass. The cockroach extract is estimated to contain about 10(3) more nucleators, active at -5 degrees C, than the grass extract.

Key concepts: Spectrometer, Thermocouple, Capillary action, Ice nucleus, Materials science, Analytical Chemistry (journal), Supercooling, Nucleation

Related papers

Back to paper searchBrowse research topicsOriginal source
A simple ice nucleation spectrometer. — Research Paper | ScholarLens