2016•Indonesian Journal of Electrical Engineering and Computer ScienceOpen access

Analysis of AC-AC Converter Based Dynamic Voltage Restorer for Maintaining Power Quality in the Transmission Line

G. Tamilvanan, Mahendran S.

Open full text 1 citations

Abstract

In the power system the major issue is to maintain the power quality .The term of power quality is to maintain the disturbance less voltage to the power system. The voltage disturbance mainly caused by voltage sag, voltage swell and harmonics presented in the system. If the system voltage is going below to the nominal voltage, then it is called as voltage sag. These power quality (PQ) events typically last for less than one second. If the system voltage is going above the nominal voltage, there it is called as voltage swell. The AC-AC converter based DVR is proposed. It can properly compensate for unlimited time duration, balanced, and as well as unbalanced voltage sag by observing the power from the grid. The pulse width modulation technique is used to triggering the switches. Only by the simple Bidirectional switches were used for generate the compensation voltage.

About this research paper

What this paper is about

In the power system the major issue is to maintain the power quality .The term of power quality is to maintain the disturbance less voltage to the power system. The voltage disturbance mainly caused by voltage sag, voltage swell and harmonics presented in the system. If the system voltage is going below to the nominal voltage, then it is called as voltage sag. These power quality (PQ) events typically last for less than one second. If the system voltage is going above the nominal voltage, there it is called as voltage swell. The AC-AC converter based DVR is proposed. It can properly compensate for unlimited time duration, balanced, and as well as unbalanced voltage sag by observing the power from the grid. The pulse width modulation technique is used to triggering the switches. Only by the simple Bidirectional switches were used for generate the compensation voltage.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In the power system the major issue is to maintain the power quality .The term of power quality is to maintain the disturbance less voltage to the power system. The voltage disturbance mainly caused by voltage sag, voltage swell and harmonics presented in the system. If the system voltage is going below to the nominal voltage, then it is called as voltage sag. These power quality (PQ) events typically last for less than one second. If the system voltage is going above the nominal voltage, there it is called as voltage swell. The AC-AC converter based DVR is proposed. It can properly compensate for unlimited time duration, balanced, and as well as unbalanced voltage sag by observing the power from the grid. The pulse width modulation technique is used to triggering the switches. Only by the simple Bidirectional switches were used for generate the compensation voltage.

Key concepts: Voltage sag, Disturbance voltage, Voltage optimisation, Harmonics, Voltage regulation, Voltage, Electrical engineering, Dropout voltage

Related papers

Back to paper searchBrowse research topicsOriginal source
Analysis of AC-AC Converter Based Dynamic Voltage Restorer for Maintaining Power Quality in the Transmission Line — Research Paper | ScholarLens