1993RadiocarbonOpen access

Extended 14C Data Base and Revised CALIB 3.0 14C Age Calibration Program

Minze Stuiver, Paula J. Reimer

Open full text 7,848 citations

Abstract

The age calibration program, CALIB (Stuiver & Reimer 1986), first made available in 1986 and subsequently modified in 1987 (revision 2.0 and 2.1), has been amended anew. The 1993 program (revision 3.0) incorporates further refinements and a new calibration data set covering nearly 22,000 cal yr (≈18,400 14C yr). The new data, and corrections to the previously used data set, derive from a 6-yr (1986–1992) time-scale calibration effort of several laboratories.

Open-access reader

About this research paper

What this paper is about

The age calibration program, CALIB (Stuiver & Reimer 1986), first made available in 1986 and subsequently modified in 1987 (revision 2.0 and 2.1), has been amended anew. The 1993 program (revision 3.0) incorporates further refinements and a new calibration data set covering nearly 22,000 cal yr (≈18,400 14C yr). The new data, and corrections to the previously used data set, derive from a 6-yr (1986–1992) time-scale calibration effort of several laboratories.

Why it matters

OpenAlex reports 7848 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The age calibration program, CALIB (Stuiver & Reimer 1986), first made available in 1986 and subsequently modified in 1987 (revision 2.0 and 2.1), has been amended anew. The 1993 program (revision 3.0) incorporates further refinements and a new calibration data set covering nearly 22,000 cal yr (≈18,400 14C yr). The new data, and corrections to the previously used data set, derive from a 6-yr (1986–1992) time-scale calibration effort of several laboratories.

Key concepts: Calibration, Data set, Base (topology), Scale (ratio), Set (abstract data type), Physics, Mathematics, Computer science

Related papers

Back to paper searchBrowse research topicsOriginal source
Extended 14C Data Base and Revised CALIB 3.0 14C Age Calibration Program — Research Paper | ScholarLens