2013•Doria (University of Helsinki)Requires access

Determination of chlorophenols from water by solid phase microextraction - ion mobility spectrometry (SPME-IMS)

Ville Luukkonen

Open publisher page 1 citations

Abstract

Chlorophenols have been classified as possible carcinogens for humans. Chlorophenols have been used as pesticides and wood preservatives. In Finland, during 1930 – 1980s, saw mills used KY-5 wood preservative that contained 2,4,6-TCP, 2,3,4,6-TeCP and PCP. Especially in Finland chlorophenols have entered the environment by leaking from contaminated grounds of old saw mills. Although chlorophenol concentrations found in environment do not cause acute concern, long term exposure can increase the risk of cancer. \nSPME is relatively cheap and simple sampling method, in which the sample extraction and concentration are performed in a single step. Solvents are not required in SPME. IMS is based on the detection of sample ion drift times. Based on the drift times, reduced mobilities are calculated, which are comparable despite the measurement conditions. SPME-IMS coupling has not been used earlier in the determination of chlorophenols from water samples. \nThe scope of this work was to study, if SPME-IMS system is suitable for detecting chloro-phenols from water samples. The aim was to determine the most optimal extraction condi-tions, which were then applied to real water samples. Following detection limits were deter-mined: 2,4,6-TCP: 0.33 mg/l; 2,3,4,6-TeCP: 0.63 mg/l and PCP: 1.63 mg/l. Detection limits were high compared to the highest possible chlorophenol concentration that is allowed in Finnish drinking water, 10 μg/l. Detected concentrations from water sample differed from verified concentrations in the case of 2,3,4,6-TeCP by 4.6 % and in the case of 2,4,6-TCP by 48.4 %. Based on the results it can be said that SPME-IMS setup is suitable for preliminary analysis of mg/l chlorophenol concentrations from water samples.

About this research paper

What this paper is about

Chlorophenols have been classified as possible carcinogens for humans. Chlorophenols have been used as pesticides and wood preservatives. In Finland, during 1930 – 1980s, saw mills used KY-5 wood preservative that contained 2,4,6-TCP, 2,3,4,6-TeCP and PCP. Especially in Finland chlorophenols have entered the environment by leaking from contaminated grounds of old saw mills. Although chlorophenol concentrations found in environment do not cause acute concern, long term exposure can increase the risk of cancer. \nSPME is relatively cheap and simple sampling method, in which the sample extraction and concentration are performed in a single step. Solvents are not required in SPME. IMS is based on the detection of sample ion drift times. Based on the drift times, reduced mobilities are calculated, which are comparable despite the measurement conditions. SPME-IMS coupling has not been used earlier in the determination of chlorophenols from water samples. \nThe scope of this work was to study, if SPME-IMS system is suitable for detecting chloro-phenols from water samples. The aim was to determine the most optimal extraction condi-tions, which were then applied to real water samples. Following detection limits were deter-mined: 2,4,6-TCP: 0.33 mg/l; 2,3,4,6-TeCP: 0.63 mg/l and PCP: 1.63 mg/l. Detection limits were high compared to the highest possible chlorophenol concentration that is allowed in Finnish drinking water, 10 μg/l. Detected concentrations from water sample differed from verified concentrations in the case of 2,3,4,6-TeCP by 4.6 % and in the case of 2,4,6-TCP by 48.4 %. Based on the results it can be said that SPME-IMS setup is suitable for preliminary analysis of mg/l chlorophenol concentrations from water samples.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Chlorophenols have been classified as possible carcinogens for humans. Chlorophenols have been used as pesticides and wood preservatives. In Finland, during 1930 – 1980s, saw mills used KY-5 wood preservative that contained 2,4,6-TCP, 2,3,4,6-TeCP and PCP. Especially in Finland chlorophenols have entered the environment by leaking from contaminated grounds of old saw mills. Although chlorophenol concentrations found in environment do not cause acute concern, long term exposure can increase the risk of cancer. \nSPME is relatively cheap and simple sampling method, in which the sample extraction and concentration are performed in a single step. Solvents are not required in SPME. IMS is based on the detection of sample ion drift times. Based on the drift times, reduced mobilities are calculated, which are comparable despite the measurement conditions. SPME-IMS coupling has not been used earlier in the determination of chlorophenols from water samples. \nThe scope of this work was to study, if SPME-IMS system is suitable for detecting chloro-phenols from water samples. The aim was to determine the most optimal extraction condi-tions, which were then applied to real water samples. Following detection limits were deter-mined: 2,4,6-TCP: 0.33 mg/l; 2,3,4,6-TeCP: 0.63 mg/l and PCP: 1.63 mg/l. Detection limits were high compared to the highest possible chlorophenol concentration that is allowed in Finnish drinking water, 10 μg/l. Detected concentrations from water sample differed from verified concentrations in the case of 2,3,4,6-TeCP by 4.6 % and in the case of 2,4,6-TCP by 48.4 %. Based on the results it can be said that SPME-IMS setup is suitable for preliminary analysis of mg/l chlorophenol concentrations from water samples.

Key concepts: Solid-phase microextraction, Ion-mobility spectrometry, Mass spectrometry, Chromatography, Chemistry, Analytical Chemistry (journal), Gas chromatography–mass spectrometry

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of chlorophenols from water by solid phase microextraction - ion mobility spectrometry (SPME-IMS) — Research Paper | ScholarLens