2015Monthly Notices of the Royal Astronomical SocietyOpen access

Accuracy of atmospheric parameters of FGK dwarfs determined by spectrum fitting

T. Ryabchikova, N. Piskunov, Yu. V. Pakhomov, V. V. Tsymbal, A. Titarenko, T. Sitnova, Sofya Alexeeva, L. Fossati, L. Mashonkina

Open full text 55 citations

Abstract

We performed extensive tests of the accuracy of atmospheric parameter determination for FGK stars based on the spectrum fitting procedure Spectroscopy Made Easy (sme). Our stellar sample consists of 13 objects, including the Sun, in the temperature range 5000–6600 K and metallicity range −1.4–+0.4. The analysed stars have the advantage of having parameters derived by interferometry. For each star, we use spectra obtained with different spectrographs and different signal-to-noise ratios (S/N). For the fitting, we adopted three different sets of constraints and test how the derived parameters depend upon the spectral regions (masks) used in sme. We developed and implemented in sme a new method for estimating uncertainties in the resulting parameters based on fitting residuals, partial derivatives, and data uncertainties. For stars in the 5700–6600 K range, the best agreement with the effective temperatures derived by interferometry is achieved when spectrum fitting includes the H α and H β lines, while for cooler stars the choice of the mask does not affect the results. The derived atmospheric parameters do not strongly depend on spectral resolution and S/N of the observations, while the uncertainties in temperature and surface gravity increase with increasing effective temperature, with minima at 50 K in Teff and 0.1 dex in log g, for spectra with S/N=150–200. A non-local thermodynamic equilibrium (NLTE) analysis of the Ti i/Ti ii and Fe i/Fe ii ionization equilibria and abundances determined from the atomic C i (NLTE) and molecular CH species supports the parameters we derived with sme by fitting the observed spectra including the hydrogen lines.

Open-access reader

About this research paper

What this paper is about

We performed extensive tests of the accuracy of atmospheric parameter determination for FGK stars based on the spectrum fitting procedure Spectroscopy Made Easy (sme). Our stellar sample consists of 13 objects, including the Sun, in the temperature range 5000–6600 K and metallicity range −1.4–+0.4. The analysed stars have the advantage of having parameters derived by interferometry. For each star, we use spectra obtained with different spectrographs and different signal-to-noise ratios (S/N). For the fitting, we adopted three different sets of constraints and test how the derived parameters depend upon the spectral regions (masks) used in sme. We developed and implemented in sme a new method for estimating uncertainties in the resulting parameters based on fitting residuals, partial derivatives, and data uncertainties. For stars in the 5700–6600 K range, the best agreement with the effective temperatures derived by interferometry is achieved when spectrum fitting includes the H α and H β lines, while for cooler stars the choice of the mask does not affect the results. The derived atmospheric parameters do not strongly depend on spectral resolution and S/N of the observations, while the uncertainties in temperature and surface gravity increase with increasing effective temperature, with minima at 50 K in Teff and 0.1 dex in log g, for spectra with S/N=150–200. A non-local thermodynamic equilibrium (NLTE) analysis of the Ti i/Ti ii and Fe i/Fe ii ionization equilibria and abundances determined from the atomic C i (NLTE) and molecular CH species supports the parameters we derived with sme by fitting the observed spectra including the hydrogen lines.

Why it matters

OpenAlex reports 55 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We performed extensive tests of the accuracy of atmospheric parameter determination for FGK stars based on the spectrum fitting procedure Spectroscopy Made Easy (sme). Our stellar sample consists of 13 objects, including the Sun, in the temperature range 5000–6600 K and metallicity range −1.4–+0.4. The analysed stars have the advantage of having parameters derived by interferometry. For each star, we use spectra obtained with different spectrographs and different signal-to-noise ratios (S/N). For the fitting, we adopted three different sets of constraints and test how the derived parameters depend upon the spectral regions (masks) used in sme. We developed and implemented in sme a new method for estimating uncertainties in the resulting parameters based on fitting residuals, partial derivatives, and data uncertainties. For stars in the 5700–6600 K range, the best agreement with the effective temperatures derived by interferometry is achieved when spectrum fitting includes the H α and H β lines, while for cooler stars the choice of the mask does not affect the results. The derived atmospheric parameters do not strongly depend on spectral resolution and S/N of the observations, while the uncertainties in temperature and surface gravity increase with increasing effective temperature, with minima at 50 K in Teff and 0.1 dex in log g, for spectra with S/N=150–200. A non-local thermodynamic equilibrium (NLTE) analysis of the Ti i/Ti ii and Fe i/Fe ii ionization equilibria and abundances determined from the atomic C i (NLTE) and molecular CH species supports the parameters we derived with sme by fitting the observed spectra including the hydrogen lines.

Key concepts: Physics, Effective temperature, Stars, Surface gravity, Metallicity, Astrophysics, Spectral line, Spectral resolution

Related papers

Back to paper searchBrowse research topicsOriginal source
Accuracy of atmospheric parameters of FGK dwarfs determined by spectrum fitting — Research Paper | ScholarLens