1998•Minerva Access (University of Melbourne)Requires access

Factors influencing gap detection in children using cochlear implants [Abstract]

P. A. Busby, Graeme M. Clark

Open publisher page 0 citations

Abstract

Two studies on gap detection were conducted with children implanted with the Cochlear Limited multiple-electrode prosthesis. In the first study, gap thresholds were measured at three pulse rates (200, 500, and 1000 pulses/s) and two stimulus durations (500 and 1000 ms) in 15 subjects. Average gap thresholds ranged from 1.8 to 32.1 ms. There was, essentially, no effect of pulse rate and in all but two subjects, no effect of stimulus duration. For these two subjects, thresholds were higher for the 1000 ms stimulus duration. In the second study, the relationships between gap thresholds and subject characteristics, and between gap thresholds and speech perception scores were examined using data from 27 subjects. A significant negative correlation between age at onset of deafness and gap thresholds was found, indicating that subjects with an earlier onset of deafness had larger gap thresholds, and most of the variability in gap thresholds was found for the congenitally deaf subjects. Gap thresholds did not correlate with other subject variables, such as duration of deafness and duration of implant use. Significant negative correlations were found between gap thresholds and word scores for open-set BKB sentences in the auditory-visual condition and the lipreading enhancement scores for the same test, indicating that subjects with poorer gap thresholds had lower speech scores. Gap thresholds did not correlate with word scores for BKB sentences in the audition alone condition, and scores for closed-set monosyllabic word tests.

About this research paper

What this paper is about

Two studies on gap detection were conducted with children implanted with the Cochlear Limited multiple-electrode prosthesis. In the first study, gap thresholds were measured at three pulse rates (200, 500, and 1000 pulses/s) and two stimulus durations (500 and 1000 ms) in 15 subjects. Average gap thresholds ranged from 1.8 to 32.1 ms. There was, essentially, no effect of pulse rate and in all but two subjects, no effect of stimulus duration. For these two subjects, thresholds were higher for the 1000 ms stimulus duration. In the second study, the relationships between gap thresholds and subject characteristics, and between gap thresholds and speech perception scores were examined using data from 27 subjects. A significant negative correlation between age at onset of deafness and gap thresholds was found, indicating that subjects with an earlier onset of deafness had larger gap thresholds, and most of the variability in gap thresholds was found for the congenitally deaf subjects. Gap thresholds did not correlate with other subject variables, such as duration of deafness and duration of implant use. Significant negative correlations were found between gap thresholds and word scores for open-set BKB sentences in the auditory-visual condition and the lipreading enhancement scores for the same test, indicating that subjects with poorer gap thresholds had lower speech scores. Gap thresholds did not correlate with word scores for BKB sentences in the audition alone condition, and scores for closed-set monosyllabic word tests.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Two studies on gap detection were conducted with children implanted with the Cochlear Limited multiple-electrode prosthesis. In the first study, gap thresholds were measured at three pulse rates (200, 500, and 1000 pulses/s) and two stimulus durations (500 and 1000 ms) in 15 subjects. Average gap thresholds ranged from 1.8 to 32.1 ms. There was, essentially, no effect of pulse rate and in all but two subjects, no effect of stimulus duration. For these two subjects, thresholds were higher for the 1000 ms stimulus duration. In the second study, the relationships between gap thresholds and subject characteristics, and between gap thresholds and speech perception scores were examined using data from 27 subjects. A significant negative correlation between age at onset of deafness and gap thresholds was found, indicating that subjects with an earlier onset of deafness had larger gap thresholds, and most of the variability in gap thresholds was found for the congenitally deaf subjects. Gap thresholds did not correlate with other subject variables, such as duration of deafness and duration of implant use. Significant negative correlations were found between gap thresholds and word scores for open-set BKB sentences in the auditory-visual condition and the lipreading enhancement scores for the same test, indicating that subjects with poorer gap thresholds had lower speech scores. Gap thresholds did not correlate with word scores for BKB sentences in the audition alone condition, and scores for closed-set monosyllabic word tests.

Key concepts: Audiology, Cochlear implant, Computer science, Psychology, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Factors influencing gap detection in children using cochlear implants [Abstract] — Research Paper | ScholarLens