2008•PubMedRequires access

Postdilatation following coronary stent deployment: lesion and procedural characteristics associated with an increase in stent dimensions.

Shahid Aziz, John L. Morris, Raphael A Perry, Rod Stables

Open publisher page 6 citations

Abstract

UNLABELLED: Adjunctive balloon postdilatation following stent deployment is often used to optimize stent expansion. However, the benefit of this strategy with modern stent delivery systems is not known. We investigated angiographic and procedural factors associated with a favorable response to postdilatation after coronary stent deployment. METHODS: We performed a prospective study recruiting 385 patients (490 lesions) who underwent stent deployment. Quantitative coronary angiography was used to measure the minimal lumen diameter (MLD) within the stent before and after postdilatation. Optimal stent deployment was defined as a stent MLD greater than or equal to 90% of the reference vessel diameter. RESULTS: Postdilatation was performed in 41.2% (202/490) of cases, with an increase in stent MLD from mean (SD) 2.50 (0.40) to 2.70 (0.38) mm, p < 0.0001. Optimal stent deployment increased from 35.6% (72/202) to 56.5% (115/202). The percentage increase in stent MLD with postdilatation was greatest in cases with a residual stenosis of > 20% after coronary stenting or a stent deployment pressure < or = 14 atm. Vessel size and predilatation had no impact on the response to postdilatation. In those cases where postdilatation was not performed, optimal stent deployment was achieved in 64.9% (187/288) of cases. CONCLUSION: A significant proportion of patients did not achieve optimal stent deployment with modern stent delivery systems. The increase in stent MLD with postdilatation was greater in cases with lower stent deployment pressures and more significant residual stenoses.

About this research paper

What this paper is about

UNLABELLED: Adjunctive balloon postdilatation following stent deployment is often used to optimize stent expansion. However, the benefit of this strategy with modern stent delivery systems is not known. We investigated angiographic and procedural factors associated with a favorable response to postdilatation after coronary stent deployment. METHODS: We performed a prospective study recruiting 385 patients (490 lesions) who underwent stent deployment. Quantitative coronary angiography was used to measure the minimal lumen diameter (MLD) within the stent before and after postdilatation. Optimal stent deployment was defined as a stent MLD greater than or equal to 90% of the reference vessel diameter. RESULTS: Postdilatation was performed in 41.2% (202/490) of cases, with an increase in stent MLD from mean (SD) 2.50 (0.40) to 2.70 (0.38) mm, p < 0.0001. Optimal stent deployment increased from 35.6% (72/202) to 56.5% (115/202). The percentage increase in stent MLD with postdilatation was greatest in cases with a residual stenosis of > 20% after coronary stenting or a stent deployment pressure < or = 14 atm. Vessel size and predilatation had no impact on the response to postdilatation. In those cases where postdilatation was not performed, optimal stent deployment was achieved in 64.9% (187/288) of cases. CONCLUSION: A significant proportion of patients did not achieve optimal stent deployment with modern stent delivery systems. The increase in stent MLD with postdilatation was greater in cases with lower stent deployment pressures and more significant residual stenoses.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

UNLABELLED: Adjunctive balloon postdilatation following stent deployment is often used to optimize stent expansion. However, the benefit of this strategy with modern stent delivery systems is not known. We investigated angiographic and procedural factors associated with a favorable response to postdilatation after coronary stent deployment. METHODS: We performed a prospective study recruiting 385 patients (490 lesions) who underwent stent deployment. Quantitative coronary angiography was used to measure the minimal lumen diameter (MLD) within the stent before and after postdilatation. Optimal stent deployment was defined as a stent MLD greater than or equal to 90% of the reference vessel diameter. RESULTS: Postdilatation was performed in 41.2% (202/490) of cases, with an increase in stent MLD from mean (SD) 2.50 (0.40) to 2.70 (0.38) mm, p < 0.0001. Optimal stent deployment increased from 35.6% (72/202) to 56.5% (115/202). The percentage increase in stent MLD with postdilatation was greatest in cases with a residual stenosis of > 20% after coronary stenting or a stent deployment pressure < or = 14 atm. Vessel size and predilatation had no impact on the response to postdilatation. In those cases where postdilatation was not performed, optimal stent deployment was achieved in 64.9% (187/288) of cases. CONCLUSION: A significant proportion of patients did not achieve optimal stent deployment with modern stent delivery systems. The increase in stent MLD with postdilatation was greater in cases with lower stent deployment pressures and more significant residual stenoses.

Key concepts: Stent, Medicine, Coronary stent, Radiology, Lumen (anatomy), Balloon, Software deployment, Coronary stenting

Related papers

Back to paper searchBrowse research topicsOriginal source
Postdilatation following coronary stent deployment: lesion and procedural characteristics associated with an increase in stent dimensions. — Research Paper | ScholarLens