Iohexol for cervical myelography via C1-C2 puncture: study of efficacy and adverse reactions.
Richard E. Latchaw, Joseph F. Sackett, P A Turski, David Shaw
Abstract
Richard E. Latchaw, Joseph F. Sackett, P A Turski, David Shaw
Abstract
Cervical myelography with iohexol via C1-C2 puncture was performed in 30 patients in two medical centers using a concentration of 240 mg l/ml. The study demonstrated iohexol to be a safe contrast medium without significant changes in neurologic and physical examination, vital signs, electrocardiogram, or hematologic or blood chemistry parameters. Fifteen patients had electroencephalograms (EEGs); two were abnormal. In one patient the baseline EEG demonstrated nonspecific slow waves in the temporal regions bilaterally that remained unchanged after myelography. In the second patient, transient changes in the left hemisphere during either hyperventilation or photic stimulation on postmyelographic EEG had not been present on the baseline recording. The relation of these changes to the drug remains unclear. Iohexol was found to be an efficacious myelographic contrast agent, with good to excellent myelograms in 93% of cases. Headache occurred in 13% and nausea in 3%.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Cervical myelography with iohexol via C1-C2 puncture was performed in 30 patients in two medical centers using a concentration of 240 mg l/ml. The study demonstrated iohexol to be a safe contrast medium without significant changes in neurologic and physical examination, vital signs, electrocardiogram, or hematologic or blood chemistry parameters. Fifteen patients had electroencephalograms (EEGs); two were abnormal. In one patient the baseline EEG demonstrated nonspecific slow waves in the temporal regions bilaterally that remained unchanged after myelography. In the second patient, transient changes in the left hemisphere during either hyperventilation or photic stimulation on postmyelographic EEG had not been present on the baseline recording. The relation of these changes to the drug remains unclear. Iohexol was found to be an efficacious myelographic contrast agent, with good to excellent myelograms in 93% of cases. Headache occurred in 13% and nausea in 3%.
Key concepts: Medicine, Iohexol, Myelography, Hyperventilation, Anesthesia, Nausea, Electroencephalography, Adverse effect