2016Journal of NeuroimmunologyRequires access

Diagnosis of myasthenia gravis: Comparison of anti-nicotinic acetyl choline receptor antibodies, repetitive nerve stimulation and Neostigmine tests at a tertiary neuro care centre in India, a ten year study

Shripad A. Patil, Suresh Bokoliya, Madhu Nagappa, Arun B. Taly

Open publisher page 20 citations

Abstract

This record does not include an abstract. Use the full-text link above if available.

About this research paper

What this paper is about

An abstract is not available in the OpenAlex record for this paper.

Why it matters

OpenAlex reports 20 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Key concepts: Myasthenia gravis, Neostigmine, Repetitive nerve stimulation, Medicine, Acetylcholine receptor, Stimulation, Choline, Nicotinic acetylcholine receptor

Related papers

Back to paper searchBrowse research topicsOriginal source
Diagnosis of myasthenia gravis: Comparison of anti-nicotinic acetyl choline receptor antibodies, repetitive nerve stimulation and Neostigmine tests at a tertiary neuro care centre in India, a ten year study — Research Paper | ScholarLens