1984•OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)Open access

Final results of the internal /sup 235/U sample intercomparison and the half-life of /sup 234/U

Wolfgang P. Poenitz, J.W. Meadows

Open full text 0 citations

Abstract

Finalized values were recieved from all laboratories which contributed samples to the /sup 235/U mass intercomparison carried out at Argonne National Laboratory. A least-squares fit was made which included the quoted masses and the absolute low-geometry and relative 2..pi..-geometry alpha data as well as the relative fission ratios measured at ANL. Correlations between the measured values were taken into account. The values quoted by the contributing laboratories were found to be within +-0.35% of the values obtained from the LS fit. Very precise values for the isotopic composition were known for two of the sample materials which permitted a determination of the half-life of /sup 234/U. The value obtained is T/sub 1/2/ = (2.457 +- 0.005) x 10/sup 5/ years. Including this value in the present data base results in a current best value of T/sub 1/2/ = (2.4566 +- 0.0044) x 10/sup 5/ years. 6 references, 2 figures, 6 tables.

Open-access reader

About this research paper

What this paper is about

Finalized values were recieved from all laboratories which contributed samples to the /sup 235/U mass intercomparison carried out at Argonne National Laboratory. A least-squares fit was made which included the quoted masses and the absolute low-geometry and relative 2..pi..-geometry alpha data as well as the relative fission ratios measured at ANL. Correlations between the measured values were taken into account. The values quoted by the contributing laboratories were found to be within +-0.35% of the values obtained from the LS fit. Very precise values for the isotopic composition were known for two of the sample materials which permitted a determination of the half-life of /sup 234/U. The value obtained is T/sub 1/2/ = (2.457 +- 0.005) x 10/sup 5/ years. Including this value in the present data base results in a current best value of T/sub 1/2/ = (2.4566 +- 0.0044) x 10/sup 5/ years. 6 references, 2 figures, 6 tables.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Finalized values were recieved from all laboratories which contributed samples to the /sup 235/U mass intercomparison carried out at Argonne National Laboratory. A least-squares fit was made which included the quoted masses and the absolute low-geometry and relative 2..pi..-geometry alpha data as well as the relative fission ratios measured at ANL. Correlations between the measured values were taken into account. The values quoted by the contributing laboratories were found to be within +-0.35% of the values obtained from the LS fit. Very precise values for the isotopic composition were known for two of the sample materials which permitted a determination of the half-life of /sup 234/U. The value obtained is T/sub 1/2/ = (2.457 +- 0.005) x 10/sup 5/ years. Including this value in the present data base results in a current best value of T/sub 1/2/ = (2.4566 +- 0.0044) x 10/sup 5/ years. 6 references, 2 figures, 6 tables.

Key concepts: Sample (material), Environmental science, Nuclear physics, Physics, Thermodynamics

Related papers

Back to paper searchBrowse research topicsOriginal source
Final results of the internal /sup 235/U sample intercomparison and the half-life of /sup 234/U — Research Paper | ScholarLens