2004•International Conference on Performance EngineeringRequires access

3-Phase Voltage Disturbance Generator for the Performance Test of A Flywheel Energy Storage UPS

J.W. Kim, K.S. Lee, Eui‐Cheol Nho, I.D.Kim, T.W. Chun, H.G. Kim, S.S. Lee

Open publisher page 0 citations

Abstract

In this paper a novel 3-phase voltage disturbance generator is described. Voltage sag, swell, outage, and unbalance can be provided by the proposed scheme. The main devices of the generator are SCR thyristors, sliding type autotransformers, and transformers, which makes the generator have good features of high reliability, high efficiency, and cost - effective system. Thus the generator can be used for the performance test of the custom power devices including UPS. The operating principle and the characteristics of the proposed scheme are analyzed and the simulation results show the usefulness of the generator.

About this research paper

What this paper is about

In this paper a novel 3-phase voltage disturbance generator is described. Voltage sag, swell, outage, and unbalance can be provided by the proposed scheme. The main devices of the generator are SCR thyristors, sliding type autotransformers, and transformers, which makes the generator have good features of high reliability, high efficiency, and cost - effective system. Thus the generator can be used for the performance test of the custom power devices including UPS. The operating principle and the characteristics of the proposed scheme are analyzed and the simulation results show the usefulness of the generator.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this paper a novel 3-phase voltage disturbance generator is described. Voltage sag, swell, outage, and unbalance can be provided by the proposed scheme. The main devices of the generator are SCR thyristors, sliding type autotransformers, and transformers, which makes the generator have good features of high reliability, high efficiency, and cost - effective system. Thus the generator can be used for the performance test of the custom power devices including UPS. The operating principle and the characteristics of the proposed scheme are analyzed and the simulation results show the usefulness of the generator.

Key concepts: Voltage sag, Generator (circuit theory), Voltage, Flywheel, Autotransformer, Transformer, Electric generator, Computer science

Related papers

Back to paper searchBrowse research topicsOriginal source
3-Phase Voltage Disturbance Generator for the Performance Test of A Flywheel Energy Storage UPS — Research Paper | ScholarLens