1963University of North Texas Digital Library (University of North Texas)Open access

AUTOMATIC EXIT STEAM QUALITY CONTROL FOR BOILING WATER REACTORS

D. Gall, Edward F. Doyle

Open full text 0 citations

Abstract

From American Nuclear Society Meeting, New York, Nov. 1963. The need for control of the flow distribution and/or steam quality in boiling reactors is discussed. A quality control device is being developed which consists of an entrance venturi and an exit venturi for measuring the flow rates into and out of the channel, means for comparing the two flow rate signals, and a value for regulating the flow rate. This device can be used either as a constantquality device or as a controlled-quality device. Results are given of air-water studies of two-phase flow in a vertical venturi. (D.L.C.)

Open-access reader

About this research paper

What this paper is about

From American Nuclear Society Meeting, New York, Nov. 1963. The need for control of the flow distribution and/or steam quality in boiling reactors is discussed. A quality control device is being developed which consists of an entrance venturi and an exit venturi for measuring the flow rates into and out of the channel, means for comparing the two flow rate signals, and a value for regulating the flow rate. This device can be used either as a constantquality device or as a controlled-quality device. Results are given of air-water studies of two-phase flow in a vertical venturi. (D.L.C.)

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

From American Nuclear Society Meeting, New York, Nov. 1963. The need for control of the flow distribution and/or steam quality in boiling reactors is discussed. A quality control device is being developed which consists of an entrance venturi and an exit venturi for measuring the flow rates into and out of the channel, means for comparing the two flow rate signals, and a value for regulating the flow rate. This device can be used either as a constantquality device or as a controlled-quality device. Results are given of air-water studies of two-phase flow in a vertical venturi. (D.L.C.)

Key concepts: Venturi effect, Vapor quality, Boiling, Volumetric flow rate, Flow (mathematics), Environmental science, Flow control (data), Boiling water reactor

Related papers