2007Unpublished venueRequires access

DESIGN AND FABRICATION OF LANGMUIR PROBE CIRCUIT FOR MEASUREMENT OF PLASMA EDGE ELECTRON TEMPERATURE AND DENSITY IN IR-T1 TOKAMAK

M Ghorannevis, S R Shariat Zadeh, Talebi Taher Ali Reza, M. K. Salem, R. Arvin, S. Mohammadi, Minhan Lou, R. Tarkeshian

Open publisher page 5 citations

Abstract

To achieve the edge plasma properties, 2 electronic circuit have been fabricated and a set of 4 single Langmuir probes installed in Iran -Tokamak1 (IR-T1). The Floating Potential has been measured without applying any voltage, Ion Saturation Current by a negative DC power supply and then by applying a sweep voltage to tips, I-V curve and so electron temperature is obtained. Then we compare these results to investigate of some properties of edge plasma.

About this research paper

What this paper is about

To achieve the edge plasma properties, 2 electronic circuit have been fabricated and a set of 4 single Langmuir probes installed in Iran -Tokamak1 (IR-T1). The Floating Potential has been measured without applying any voltage, Ion Saturation Current by a negative DC power supply and then by applying a sweep voltage to tips, I-V curve and so electron temperature is obtained. Then we compare these results to investigate of some properties of edge plasma.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

To achieve the edge plasma properties, 2 electronic circuit have been fabricated and a set of 4 single Langmuir probes installed in Iran -Tokamak1 (IR-T1). The Floating Potential has been measured without applying any voltage, Ion Saturation Current by a negative DC power supply and then by applying a sweep voltage to tips, I-V curve and so electron temperature is obtained. Then we compare these results to investigate of some properties of edge plasma.

Key concepts: Langmuir probe, Tokamak, Electron temperature, Saturation current, Plasma, Materials science, Plasma diagnostics, Plasma parameters

Related papers

Back to paper searchBrowse research topicsOriginal source
DESIGN AND FABRICATION OF LANGMUIR PROBE CIRCUIT FOR MEASUREMENT OF PLASMA EDGE ELECTRON TEMPERATURE AND DENSITY IN IR-T1 TOKAMAK — Research Paper | ScholarLens