이중외피의 개구부 계획에 따른 환기 및 냉방에너지성능 평가

김경찬, 성욱주, 조수, 심경종, 이효진

Open publisher page 0 citations

Abstract

In this study, natural ventilation and energy performance of multi-stories type double skin facade(DSF) was evaluated according to its opening design. The objective of this study is to suggest design method for reducing cooling load of office building with DSF. Energyplus simulation with airflow network is conducted to analyze on thermal, airflow condition and indoor cooling load of each alternative. The validation of simulation baseline is referenced by the methods and results of previous study entitled ‘An Analysis on Method and Applicability for Invigorating Airflow in Intermediate Space of Double Skin Facade during Cooling Season.(Sung et al., 2012)’. Using the simulation baseline of the previous study, natural ventilation and indoor cooling energy performance is analyzed by air temperature and total pressure according to opening and wind direction at upper part of DSF. As results of this study, ALT2 applied top side opening reacts to outdoor wind direction flexibly, and shows excellent performance in terms of the natural ventilation(49.3% improvement compared to the Baseline) and the indoor cooling load(5.9% improvement compared to the Baseline).

About this research paper

What this paper is about

In this study, natural ventilation and energy performance of multi-stories type double skin facade(DSF) was evaluated according to its opening design. The objective of this study is to suggest design method for reducing cooling load of office building with DSF. Energyplus simulation with airflow network is conducted to analyze on thermal, airflow condition and indoor cooling load of each alternative. The validation of simulation baseline is referenced by the methods and results of previous study entitled ‘An Analysis on Method and Applicability for Invigorating Airflow in Intermediate Space of Double Skin Facade during Cooling Season.(Sung et al., 2012)’. Using the simulation baseline of the previous study, natural ventilation and indoor cooling energy performance is analyzed by air temperature and total pressure according to opening and wind direction at upper part of DSF. As results of this study, ALT2 applied top side opening reacts to outdoor wind direction flexibly, and shows excellent performance in terms of the natural ventilation(49.3% improvement compared to the Baseline) and the indoor cooling load(5.9% improvement compared to the Baseline).

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this study, natural ventilation and energy performance of multi-stories type double skin facade(DSF) was evaluated according to its opening design. The objective of this study is to suggest design method for reducing cooling load of office building with DSF. Energyplus simulation with airflow network is conducted to analyze on thermal, airflow condition and indoor cooling load of each alternative. The validation of simulation baseline is referenced by the methods and results of previous study entitled ‘An Analysis on Method and Applicability for Invigorating Airflow in Intermediate Space of Double Skin Facade during Cooling Season.(Sung et al., 2012)’. Using the simulation baseline of the previous study, natural ventilation and indoor cooling energy performance is analyzed by air temperature and total pressure according to opening and wind direction at upper part of DSF. As results of this study, ALT2 applied top side opening reacts to outdoor wind direction flexibly, and shows excellent performance in terms of the natural ventilation(49.3% improvement compared to the Baseline) and the indoor cooling load(5.9% improvement compared to the Baseline).

Key concepts: Natural ventilation, Airflow, Cooling load, Facade, Ventilation (architecture), Environmental science, Thermal comfort, Baseline (sea)