2011DOAJ (DOAJ: Directory of Open Access Journals)Open access

COMPARISON OF THE QUALITY OF POPLAR LUMBER IN THE UPPER, MIDDLE AND LOWER ROWS OF WOOD DRYING KILN

Sohrab Rahimi, M Faezipour, Saeid Eshaghi, Asghar Tarmian

Open full text 1 citations

Abstract

Poplar lumbers with nominal thickness of 5 cm from Taleghan region, located in west of Karaj were dried under three different schedules including T8-F4 (recommended schedule by F.P.L for poplar), T8-F5 and T9-F4. The purpose of this research was to study the effects of the kiln’s rows (upper, middle, lower) on the quality of the dried boards. Dry bulb temperatures for the schedules were adjusted at 54, 54 and 60 °C, while the final temperatures were adjusted at 82, 82 and 71 °C, respectively. The severity of warping, internal checking and surface checking in kiln dried lumbers were measured and analyzed. The results indicated that the boards in upper, middle and lower rows of the kiln, in all three schedules, did not have any significant difference in 95% confidence interval. Also, the final moisture content of the boards in all three rows and all three schedules were in acceptable quality.

About this research paper

What this paper is about

Poplar lumbers with nominal thickness of 5 cm from Taleghan region, located in west of Karaj were dried under three different schedules including T8-F4 (recommended schedule by F.P.L for poplar), T8-F5 and T9-F4. The purpose of this research was to study the effects of the kiln’s rows (upper, middle, lower) on the quality of the dried boards. Dry bulb temperatures for the schedules were adjusted at 54, 54 and 60 °C, while the final temperatures were adjusted at 82, 82 and 71 °C, respectively. The severity of warping, internal checking and surface checking in kiln dried lumbers were measured and analyzed. The results indicated that the boards in upper, middle and lower rows of the kiln, in all three schedules, did not have any significant difference in 95% confidence interval. Also, the final moisture content of the boards in all three rows and all three schedules were in acceptable quality.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Poplar lumbers with nominal thickness of 5 cm from Taleghan region, located in west of Karaj were dried under three different schedules including T8-F4 (recommended schedule by F.P.L for poplar), T8-F5 and T9-F4. The purpose of this research was to study the effects of the kiln’s rows (upper, middle, lower) on the quality of the dried boards. Dry bulb temperatures for the schedules were adjusted at 54, 54 and 60 °C, while the final temperatures were adjusted at 82, 82 and 71 °C, respectively. The severity of warping, internal checking and surface checking in kiln dried lumbers were measured and analyzed. The results indicated that the boards in upper, middle and lower rows of the kiln, in all three schedules, did not have any significant difference in 95% confidence interval. Also, the final moisture content of the boards in all three rows and all three schedules were in acceptable quality.

Key concepts: Kiln, Pulp and paper industry, Wood drying, Quality (philosophy), Environmental science, Mathematics, Waste management, Materials science

Related papers

Back to paper searchBrowse research topicsOriginal source
COMPARISON OF THE QUALITY OF POPLAR LUMBER IN THE UPPER, MIDDLE AND LOWER ROWS OF WOOD DRYING KILN — Research Paper | ScholarLens