2014Asian Journal of Pharmaceutical AnalysisRequires access

Development and Validation of a Reversed-Phase HPLC Method For Simultaneous Determination of Aspirin, Atenolol and Amlodipine in Capsules Dosage Forms

Kumaraswamy Gandla, N. Ravindra, B. Jyothsna

Open publisher page 3 citations

Abstract

A simple, accurate, rapid and precise isocratic reversed-phase high-performance liquid chromatographic method has been developed and validated for simultaneous determination of Aspirin, Amlodipine and Atenolol in capsules. The chromatographic separation was carried out on an Cosmosil packed C18-MS-II(4.6 I.D.x250mm; 5μ particle size) with a mixture of acetonitrile: ammonium acetate buffer pH 4.6 adjusted with 30%v/v acetic acid (80:20, v/v) as mobile phase; at a flow rate of 0.8 ml/min. UV detection was performed at 233 nm. The retention times were 4.415, 3.688 and 3.001 min. for Aspirin, Amlodipine and Atenolol, respectively. Calibration plots were linear (r2>0.998) over the concentration range 1–6 μg/ml for Amlodipine, 5–30 μg/ml for Aspirin and 2.5–15 μg/ml Atenolol. The method was validated for accuracy, precision, specificity, linearity, and sensitivity. The proposed method was successfully used for quantitative analysis of capsules. No interference from any component of pharmaceutical dosage form was observed. Validation studies revealed that method is specific, rapid, reliable, and reproducible. The high recovery and low relative standard deviation confirm the suitability of the method for routine determination of Aspirin, Amlodipine and Atenolol in bulk drug and capsule dosage form.

About this research paper

What this paper is about

A simple, accurate, rapid and precise isocratic reversed-phase high-performance liquid chromatographic method has been developed and validated for simultaneous determination of Aspirin, Amlodipine and Atenolol in capsules. The chromatographic separation was carried out on an Cosmosil packed C18-MS-II(4.6 I.D.x250mm; 5μ particle size) with a mixture of acetonitrile: ammonium acetate buffer pH 4.6 adjusted with 30%v/v acetic acid (80:20, v/v) as mobile phase; at a flow rate of 0.8 ml/min. UV detection was performed at 233 nm. The retention times were 4.415, 3.688 and 3.001 min. for Aspirin, Amlodipine and Atenolol, respectively. Calibration plots were linear (r2>0.998) over the concentration range 1–6 μg/ml for Amlodipine, 5–30 μg/ml for Aspirin and 2.5–15 μg/ml Atenolol. The method was validated for accuracy, precision, specificity, linearity, and sensitivity. The proposed method was successfully used for quantitative analysis of capsules. No interference from any component of pharmaceutical dosage form was observed. Validation studies revealed that method is specific, rapid, reliable, and reproducible. The high recovery and low relative standard deviation confirm the suitability of the method for routine determination of Aspirin, Amlodipine and Atenolol in bulk drug and capsule dosage form.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A simple, accurate, rapid and precise isocratic reversed-phase high-performance liquid chromatographic method has been developed and validated for simultaneous determination of Aspirin, Amlodipine and Atenolol in capsules. The chromatographic separation was carried out on an Cosmosil packed C18-MS-II(4.6 I.D.x250mm; 5μ particle size) with a mixture of acetonitrile: ammonium acetate buffer pH 4.6 adjusted with 30%v/v acetic acid (80:20, v/v) as mobile phase; at a flow rate of 0.8 ml/min. UV detection was performed at 233 nm. The retention times were 4.415, 3.688 and 3.001 min. for Aspirin, Amlodipine and Atenolol, respectively. Calibration plots were linear (r2>0.998) over the concentration range 1–6 μg/ml for Amlodipine, 5–30 μg/ml for Aspirin and 2.5–15 μg/ml Atenolol. The method was validated for accuracy, precision, specificity, linearity, and sensitivity. The proposed method was successfully used for quantitative analysis of capsules. No interference from any component of pharmaceutical dosage form was observed. Validation studies revealed that method is specific, rapid, reliable, and reproducible. The high recovery and low relative standard deviation confirm the suitability of the method for routine determination of Aspirin, Amlodipine and Atenolol in bulk drug and capsule dosage form.

Key concepts: Atenolol, Amlodipine, Chromatography, Dosage form, Aspirin, Chemistry, Ammonium acetate, Relative standard deviation