2003DOAJ (DOAJ: Directory of Open Access Journals)Open access

Pressor responses and intraocular pressure changes following insertion of laryngeal mask airway : Comparison with tracheal tube insertion.

Syed Altaf Bukhari, Imtiaz Naqash, Javed Zargar, Showkat Nengroo, Abdul Waheed Mir

Open full text 16 citations

Abstract

SUMMARY In a prospective randomized study pressor responses and intraocular pressure changes following insertion of laryngeal mask airway and endotracheal tube were compared in two groups of twenty five patients each undergoing elective non-ophthalmic surgical procedures. In group I, laryngeal mask airway was used whereas in group II endotracheal tube was inserted. Baseline and pre-insertion values of heart rate, systolic blood pressure, diastolic blood pressure and intraocular pressure were recorded and repeated at one, two and three minutes after insertion of laryngeal mask airway or endotracheal tube. Our results showed a significant increase in systolic and diastolic blood pressure as well as in intraocular pressure in endotracheal tube group as compared to laryngeal mask airway group (p<0.01). Heart rate showed an increase in both the groups but the difference was statistically insignificant. It was concluded from the study that the use of laryngeal mask airway might offer some advantages in patients where minimal changes in hemodynamics and intraocular pressure are desirable.

About this research paper

What this paper is about

SUMMARY In a prospective randomized study pressor responses and intraocular pressure changes following insertion of laryngeal mask airway and endotracheal tube were compared in two groups of twenty five patients each undergoing elective non-ophthalmic surgical procedures. In group I, laryngeal mask airway was used whereas in group II endotracheal tube was inserted. Baseline and pre-insertion values of heart rate, systolic blood pressure, diastolic blood pressure and intraocular pressure were recorded and repeated at one, two and three minutes after insertion of laryngeal mask airway or endotracheal tube. Our results showed a significant increase in systolic and diastolic blood pressure as well as in intraocular pressure in endotracheal tube group as compared to laryngeal mask airway group (p<0.01). Heart rate showed an increase in both the groups but the difference was statistically insignificant. It was concluded from the study that the use of laryngeal mask airway might offer some advantages in patients where minimal changes in hemodynamics and intraocular pressure are desirable.

Why it matters

OpenAlex reports 16 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

SUMMARY In a prospective randomized study pressor responses and intraocular pressure changes following insertion of laryngeal mask airway and endotracheal tube were compared in two groups of twenty five patients each undergoing elective non-ophthalmic surgical procedures. In group I, laryngeal mask airway was used whereas in group II endotracheal tube was inserted. Baseline and pre-insertion values of heart rate, systolic blood pressure, diastolic blood pressure and intraocular pressure were recorded and repeated at one, two and three minutes after insertion of laryngeal mask airway or endotracheal tube. Our results showed a significant increase in systolic and diastolic blood pressure as well as in intraocular pressure in endotracheal tube group as compared to laryngeal mask airway group (p<0.01). Heart rate showed an increase in both the groups but the difference was statistically insignificant. It was concluded from the study that the use of laryngeal mask airway might offer some advantages in patients where minimal changes in hemodynamics and intraocular pressure are desirable.

Key concepts: Medicine, Anesthesia, Laryngeal mask airway, Intraocular pressure, Airway, Blood pressure, Heart rate, Hemodynamics

Related papers

Back to paper searchBrowse research topicsOriginal source
Pressor responses and intraocular pressure changes following insertion of laryngeal mask airway : Comparison with tracheal tube insertion. — Research Paper | ScholarLens