1991European Heart JournalRequires access

Assessment of severity of aortic regurgitation by M-mode colour Doppler flow imaging

Christophe Tribouilloy, Wei Feng Shen, M. Slama, Jean-Luc Rey, H. DUFOSSÉ, D Choquet, J P Lesbre

Open publisher page 21 citations

Abstract

To assess the value of measuring the aortic regurgitant jet diameter at its origin by M-mode colour Doppler imaging, 82 patients with aortic regurgitation underwent, within 72 h of each other, colour Doppler examination and angiography. After excluding one patient without colour Doppler aortic regurgitation and five with a highly eccentric regurgitant jet, we found a close relationship between the jet diameter at its origin measured by M-mode colour Doppler and the angiographic grade of aortic regurgitation (r = 0.88). A jet diameter greater than or equal to 12 mm identified severe aortic regurgitation (grade III or IV) with a sensitivity of 86.4% and a specificity of 94.4%. In 38 patients, the jet diameter correlated well with the regurgitant fraction measured by a combined haemodynamic-angiographic method (r = 0.88). A jet diameter greater than or equal to 12 mm identified a regurgitant fraction greater than or equal to 40% with a sensitivity of 88.2% and a specificity of 95.2%. This study indicates that the size of the regurgitant jet diameter at its origin measured by M-mode colour Doppler provides a simple and useful measure of the severity of aortic regurgitation. It may allow differentiation between mild or moderate and severe aortic regurgitation and evaluation of regurgitant fraction.

About this research paper

What this paper is about

To assess the value of measuring the aortic regurgitant jet diameter at its origin by M-mode colour Doppler imaging, 82 patients with aortic regurgitation underwent, within 72 h of each other, colour Doppler examination and angiography. After excluding one patient without colour Doppler aortic regurgitation and five with a highly eccentric regurgitant jet, we found a close relationship between the jet diameter at its origin measured by M-mode colour Doppler and the angiographic grade of aortic regurgitation (r = 0.88). A jet diameter greater than or equal to 12 mm identified severe aortic regurgitation (grade III or IV) with a sensitivity of 86.4% and a specificity of 94.4%. In 38 patients, the jet diameter correlated well with the regurgitant fraction measured by a combined haemodynamic-angiographic method (r = 0.88). A jet diameter greater than or equal to 12 mm identified a regurgitant fraction greater than or equal to 40% with a sensitivity of 88.2% and a specificity of 95.2%. This study indicates that the size of the regurgitant jet diameter at its origin measured by M-mode colour Doppler provides a simple and useful measure of the severity of aortic regurgitation. It may allow differentiation between mild or moderate and severe aortic regurgitation and evaluation of regurgitant fraction.

Why it matters

OpenAlex reports 21 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

To assess the value of measuring the aortic regurgitant jet diameter at its origin by M-mode colour Doppler imaging, 82 patients with aortic regurgitation underwent, within 72 h of each other, colour Doppler examination and angiography. After excluding one patient without colour Doppler aortic regurgitation and five with a highly eccentric regurgitant jet, we found a close relationship between the jet diameter at its origin measured by M-mode colour Doppler and the angiographic grade of aortic regurgitation (r = 0.88). A jet diameter greater than or equal to 12 mm identified severe aortic regurgitation (grade III or IV) with a sensitivity of 86.4% and a specificity of 94.4%. In 38 patients, the jet diameter correlated well with the regurgitant fraction measured by a combined haemodynamic-angiographic method (r = 0.88). A jet diameter greater than or equal to 12 mm identified a regurgitant fraction greater than or equal to 40% with a sensitivity of 88.2% and a specificity of 95.2%. This study indicates that the size of the regurgitant jet diameter at its origin measured by M-mode colour Doppler provides a simple and useful measure of the severity of aortic regurgitation. It may allow differentiation between mild or moderate and severe aortic regurgitation and evaluation of regurgitant fraction.

Key concepts: Regurgitation (circulation), Medicine, Regurgitant fraction, Cardiology, Doppler effect, Internal medicine, Angiography, Jet (fluid)

Related papers

Back to paper searchBrowse research topicsOriginal source
Assessment of severity of aortic regurgitation by M-mode colour Doppler flow imaging — Research Paper | ScholarLens