Effects of lung volume on lung and chest wall mechanics in rats
Toyohiro Hirai, K. A. McKeown, R. F. M. Gomes, Jason H. T. Bates
Abstract
Toyohiro Hirai, K. A. McKeown, R. F. M. Gomes, Jason H. T. Bates
Abstract
To investigate the effect of lung volume on chest wall and lung mechanics in the rats, we measured the impedance (Z) under closed- and open-chest conditions at various positive end-expiratory pressures (0-0.9 kPa) by using a computer-controlled small-animal ventilator (T. F. Schuessler and J. H. T. Bates. IEEE Trans. Biomed. Eng. 42: 860-866, 1995) that we have developed for determining accurately the respiratory Z in small animals. The Z of total respiratory system and lungs was measured with small-volume oscillations between 0.25 and 9.125 Hz. The measured Z was fitted to a model that featured a constant-phase tissue compartment (with dissipation and elastance characterized by constants G and H, respectively) and a constant airway resistance (Z. Hantos, B. Daroczy, B. Suki, S. Nagy, and J. J. Fredberg. J. Appl. Physiol. 72: 168-178, 1992). We matched the lung volume between the closed- and open-chest conditions by using the quasi-static pressure-volume relationship of the lungs to calculate Z as a function of lung volume. Resistance decreased with lung volume and was not significantly different between total respiratory system and lungs. However, G and H of the respiratory system were significantly higher than those of the lungs. We conclude that chest wall in rats has a significant influence on tissue mechanics of the total respiratory system.
OpenAlex reports 130 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
To investigate the effect of lung volume on chest wall and lung mechanics in the rats, we measured the impedance (Z) under closed- and open-chest conditions at various positive end-expiratory pressures (0-0.9 kPa) by using a computer-controlled small-animal ventilator (T. F. Schuessler and J. H. T. Bates. IEEE Trans. Biomed. Eng. 42: 860-866, 1995) that we have developed for determining accurately the respiratory Z in small animals. The Z of total respiratory system and lungs was measured with small-volume oscillations between 0.25 and 9.125 Hz. The measured Z was fitted to a model that featured a constant-phase tissue compartment (with dissipation and elastance characterized by constants G and H, respectively) and a constant airway resistance (Z. Hantos, B. Daroczy, B. Suki, S. Nagy, and J. J. Fredberg. J. Appl. Physiol. 72: 168-178, 1992). We matched the lung volume between the closed- and open-chest conditions by using the quasi-static pressure-volume relationship of the lungs to calculate Z as a function of lung volume. Resistance decreased with lung volume and was not significantly different between total respiratory system and lungs. However, G and H of the respiratory system were significantly higher than those of the lungs. We conclude that chest wall in rats has a significant influence on tissue mechanics of the total respiratory system.
Key concepts: Respiratory system, Lung volumes, Lung, Respiratory physiology, Airway resistance, Medicine, Tidal volume, Cardiology