2007VTechWorks (Virginia Tech)Requires access

Development of the Passive Perfusion Probe for Non-Invasive Blood Perfusion Measurement

Patricia L. Ricketts

Open publisher page 0 citations

Abstract

A non-invasive blood perfusion system has been developed and tested in a phantom tissue and an animal model. The system uses a small sensor with a laminated flat thermocouple to measure the heat transfer response to an arbitrary thermal event (convective or conductive) imposed on the tissue surface. Blood perfusion and contact resistance are estimated by comparing heat flux data with a mathematical model of the tissue. The perfusion system was evaluated for repeatability and sensitivity using both a phantom tissue test stand and exposed rat liver tests. Perfusion in the phantom tissue tests was varied by controlling the flow of water into the phantom tissue test section, and the perfusion in the exposed liver tests was varied by temporarily occluding blood flow through the portal vein. The phantom tissue tests indicated that the probe can be used to detect small changes in perfusion (0.009 ml/ml/s). The probe qualitatively tracked the changes in the perfusion of the liver model due to occlusion of the portal vein.

About this research paper

What this paper is about

A non-invasive blood perfusion system has been developed and tested in a phantom tissue and an animal model. The system uses a small sensor with a laminated flat thermocouple to measure the heat transfer response to an arbitrary thermal event (convective or conductive) imposed on the tissue surface. Blood perfusion and contact resistance are estimated by comparing heat flux data with a mathematical model of the tissue. The perfusion system was evaluated for repeatability and sensitivity using both a phantom tissue test stand and exposed rat liver tests. Perfusion in the phantom tissue tests was varied by controlling the flow of water into the phantom tissue test section, and the perfusion in the exposed liver tests was varied by temporarily occluding blood flow through the portal vein. The phantom tissue tests indicated that the probe can be used to detect small changes in perfusion (0.009 ml/ml/s). The probe qualitatively tracked the changes in the perfusion of the liver model due to occlusion of the portal vein.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A non-invasive blood perfusion system has been developed and tested in a phantom tissue and an animal model. The system uses a small sensor with a laminated flat thermocouple to measure the heat transfer response to an arbitrary thermal event (convective or conductive) imposed on the tissue surface. Blood perfusion and contact resistance are estimated by comparing heat flux data with a mathematical model of the tissue. The perfusion system was evaluated for repeatability and sensitivity using both a phantom tissue test stand and exposed rat liver tests. Perfusion in the phantom tissue tests was varied by controlling the flow of water into the phantom tissue test section, and the perfusion in the exposed liver tests was varied by temporarily occluding blood flow through the portal vein. The phantom tissue tests indicated that the probe can be used to detect small changes in perfusion (0.009 ml/ml/s). The probe qualitatively tracked the changes in the perfusion of the liver model due to occlusion of the portal vein.

Key concepts: Perfusion, Perfusion scanning, Medicine, Biomedical engineering, Computer science, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Development of the Passive Perfusion Probe for Non-Invasive Blood Perfusion Measurement — Research Paper | ScholarLens