2015IJSRD : international journal for scientific research and developmentRequires access

Soft Start of an Induction Motor with Reduction in Torque Pulsations during Starting

Shweta V. Muttagi, M.S. Aspalli

Open publisher page 0 citations

Abstract

This project deals with the thyristorised soft starting of 3 phase Induction Motor. Three phase induction motors of ratings beyond 50KW when started directly from a 3 phase supply draws 3 to 5 times the rated current and starting torque can be 2 times larger than in the normal operation. These high starting current will cause overheating of the windings and a large voltage drop and influence the normal operation of the motor when connected to the main power supply. Large starting torque pulsations may cause severe mechanical stress on the shaft of the motor and the load. So it is necessary to control motor starting current value. Solid state starters or Soft Starters are designed to control such starting current of the motor. Soft starter is done by connecting SCR s in antiparallel in each phase. The voltage to the stator terminals can be controlled by varying the conduction period of thyristors. The high starting current can be considerably reduced by soft start, thereby the electrical and mechanical stress on the motor can be minimized. Energy saving during starting can also be achieved and hence losses can also be minimized. The soft starter is developed for 3 Phase, 440V, 50Hz 1HP induction motor and is tested in laboratory. The starting current of the induction motor with and without soft starter are observed and tabulated. It is observed that the starting high inrush current is reduced to 30 to 50% of its rated value thus minimizing the starting torque pulsations and increasing the life of the motor.

About this research paper

What this paper is about

This project deals with the thyristorised soft starting of 3 phase Induction Motor. Three phase induction motors of ratings beyond 50KW when started directly from a 3 phase supply draws 3 to 5 times the rated current and starting torque can be 2 times larger than in the normal operation. These high starting current will cause overheating of the windings and a large voltage drop and influence the normal operation of the motor when connected to the main power supply. Large starting torque pulsations may cause severe mechanical stress on the shaft of the motor and the load. So it is necessary to control motor starting current value. Solid state starters or Soft Starters are designed to control such starting current of the motor. Soft starter is done by connecting SCR s in antiparallel in each phase. The voltage to the stator terminals can be controlled by varying the conduction period of thyristors. The high starting current can be considerably reduced by soft start, thereby the electrical and mechanical stress on the motor can be minimized. Energy saving during starting can also be achieved and hence losses can also be minimized. The soft starter is developed for 3 Phase, 440V, 50Hz 1HP induction motor and is tested in laboratory. The starting current of the induction motor with and without soft starter are observed and tabulated. It is observed that the starting high inrush current is reduced to 30 to 50% of its rated value thus minimizing the starting torque pulsations and increasing the life of the motor.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This project deals with the thyristorised soft starting of 3 phase Induction Motor. Three phase induction motors of ratings beyond 50KW when started directly from a 3 phase supply draws 3 to 5 times the rated current and starting torque can be 2 times larger than in the normal operation. These high starting current will cause overheating of the windings and a large voltage drop and influence the normal operation of the motor when connected to the main power supply. Large starting torque pulsations may cause severe mechanical stress on the shaft of the motor and the load. So it is necessary to control motor starting current value. Solid state starters or Soft Starters are designed to control such starting current of the motor. Soft starter is done by connecting SCR s in antiparallel in each phase. The voltage to the stator terminals can be controlled by varying the conduction period of thyristors. The high starting current can be considerably reduced by soft start, thereby the electrical and mechanical stress on the motor can be minimized. Energy saving during starting can also be achieved and hence losses can also be minimized. The soft starter is developed for 3 Phase, 440V, 50Hz 1HP induction motor and is tested in laboratory. The starting current of the induction motor with and without soft starter are observed and tabulated. It is observed that the starting high inrush current is reduced to 30 to 50% of its rated value thus minimizing the starting torque pulsations and increasing the life of the motor.

Key concepts: Motor soft starter, Induction motor, Torque, Control theory (sociology), Inrush current, Electromagnetic coil, Overheating (electricity), Thyristor

Related papers

Back to paper searchBrowse research topicsOriginal source
Soft Start of an Induction Motor with Reduction in Torque Pulsations during Starting — Research Paper | ScholarLens