Simultaneous Estimation and Validation of Amlodipine Besylate and Nebivolol Hydrochloride in Tablet Formulation by RP-HPLC Method
M. Jagadeeswaran, N. Madana Gopal, Sivakumar Thangavel
Abstract
M. Jagadeeswaran, N. Madana Gopal, Sivakumar Thangavel
Abstract
A simple, selective and rapid reversed phase high performance liquid chromatographic (RP-HPLC) method has been developed for the simultaneous estimation of Amlodipine Besylate and Nebivolol Hydrochloride from their tablet formulation. The method is carried out on a nucleosil C18 (25 cm×4.6 mm) column with the mobile phase consisting of 0.01M tetra butyl ammonium hydrogen sulphate: acetonitrile (60:40 v/v) and adjusted the pH to 3.0 by using trimethyl amine, at the flow rate of 1.0 ml min−1. Detection is performed at 264 nm. The retention time of Amlodipine Besylate and Nebivolol Hydrochloride was 2.55 and 5.44 min respectively. The developed method was validated for linearity, accuracy, precision, solution stability, robustness, limit of detection, and limit of quantification. The proposed method can be used for routine analysis of drugs in combined dosage forms.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A simple, selective and rapid reversed phase high performance liquid chromatographic (RP-HPLC) method has been developed for the simultaneous estimation of Amlodipine Besylate and Nebivolol Hydrochloride from their tablet formulation. The method is carried out on a nucleosil C18 (25 cm×4.6 mm) column with the mobile phase consisting of 0.01M tetra butyl ammonium hydrogen sulphate: acetonitrile (60:40 v/v) and adjusted the pH to 3.0 by using trimethyl amine, at the flow rate of 1.0 ml min−1. Detection is performed at 264 nm. The retention time of Amlodipine Besylate and Nebivolol Hydrochloride was 2.55 and 5.44 min respectively. The developed method was validated for linearity, accuracy, precision, solution stability, robustness, limit of detection, and limit of quantification. The proposed method can be used for routine analysis of drugs in combined dosage forms.
Key concepts: Amlodipine, Chromatography, Detection limit, Chemistry, Nebivolol, High-performance liquid chromatography, Acetonitrile, Pharmaceutical formulation