2002Southern African Journal of Anaesthesia and AnalgesiaOpen access

The intubating laryngeal mask produces less heart rate response to intubation than conventional laryngoscopy : research article

N.R. Evans, M. F. M. James

Open full text 0 citations

Abstract

We compared heart rate and blood pressure changes to intubation produced by conventional laryngoscopic-guided intubation to those produced by blind intubation through the intubating laryngeal mask (ILM) in normotensive adults with normal airways. Forty paralysed, anaesthetised adults undergoing elective surgery were randomly assigned to one of two groups : 1. Blind intubation through the ILM using a straight silicone tracheal tube manufactured for specific use with the ILM; 2. Intubation with a size 3 macintosh laryngoscope using a polyvinyl chloride tube. Intubation success rate, number of intubation attempts, time to intubation were recorded. Heart rate and non-invasive blood pressure preinduction, preintubation and at one minute intervals after intubation until ten minutes post intubation were recorded. The intubation success rate was 90% (68% first attempt) for the ILM group and 100% (all first attempt) for the laryngoscopic group. Time to successful intubation was longer (50 vs 22s) and more intubation attempts were required in the ILM group (p<0.0001). Changes from pre-intubation values showed a significantly lower heart rate response in the ILM group at 4 to 10 minutes post intubation (p<0.05). The ILM may have a role in managing the intubation response in patients where an increase in heart rate is associated with an increased risk, such as in patients with ischaemic heart disease.

About this research paper

What this paper is about

We compared heart rate and blood pressure changes to intubation produced by conventional laryngoscopic-guided intubation to those produced by blind intubation through the intubating laryngeal mask (ILM) in normotensive adults with normal airways. Forty paralysed, anaesthetised adults undergoing elective surgery were randomly assigned to one of two groups : 1. Blind intubation through the ILM using a straight silicone tracheal tube manufactured for specific use with the ILM; 2. Intubation with a size 3 macintosh laryngoscope using a polyvinyl chloride tube. Intubation success rate, number of intubation attempts, time to intubation were recorded. Heart rate and non-invasive blood pressure preinduction, preintubation and at one minute intervals after intubation until ten minutes post intubation were recorded. The intubation success rate was 90% (68% first attempt) for the ILM group and 100% (all first attempt) for the laryngoscopic group. Time to successful intubation was longer (50 vs 22s) and more intubation attempts were required in the ILM group (p<0.0001). Changes from pre-intubation values showed a significantly lower heart rate response in the ILM group at 4 to 10 minutes post intubation (p<0.05). The ILM may have a role in managing the intubation response in patients where an increase in heart rate is associated with an increased risk, such as in patients with ischaemic heart disease.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We compared heart rate and blood pressure changes to intubation produced by conventional laryngoscopic-guided intubation to those produced by blind intubation through the intubating laryngeal mask (ILM) in normotensive adults with normal airways. Forty paralysed, anaesthetised adults undergoing elective surgery were randomly assigned to one of two groups : 1. Blind intubation through the ILM using a straight silicone tracheal tube manufactured for specific use with the ILM; 2. Intubation with a size 3 macintosh laryngoscope using a polyvinyl chloride tube. Intubation success rate, number of intubation attempts, time to intubation were recorded. Heart rate and non-invasive blood pressure preinduction, preintubation and at one minute intervals after intubation until ten minutes post intubation were recorded. The intubation success rate was 90% (68% first attempt) for the ILM group and 100% (all first attempt) for the laryngoscopic group. Time to successful intubation was longer (50 vs 22s) and more intubation attempts were required in the ILM group (p<0.0001). Changes from pre-intubation values showed a significantly lower heart rate response in the ILM group at 4 to 10 minutes post intubation (p<0.05). The ILM may have a role in managing the intubation response in patients where an increase in heart rate is associated with an increased risk, such as in patients with ischaemic heart disease.

Key concepts: Intubation, Medicine, Laryngoscopy, Anesthesia, Heart rate, Tracheal intubation, Blood pressure, Elective surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
The intubating laryngeal mask produces less heart rate response to intubation than conventional laryngoscopy : research article — Research Paper | ScholarLens