A simple RP-HPLC method for determining imidacloprid residues in goat tissues.
Gayatri Dewangan, Akhilesh Kumar Mishra, Tapan Kumar M
Abstract
Gayatri Dewangan, Akhilesh Kumar Mishra, Tapan Kumar M
Abstract
The present work is aimed to develop a rapid, simple, sensitive and reliable reverse phase high performance liquid chromatography (RP-HPLC) method of imidacloprid and its residues in different substrates of goat tissues. Separation was achieved using C-18 column with mobile phase consisting of acetonitrile and purified HPLC grade water. The method consists of extracting with acetonitrile from different tissues and cleans up with acetonitrile and hexane (50%) mixture. Quantification was performed by reverse phase (RP) HPLC with PDA detector. The chromatogram showed a well-resolved peak of imidacloprid, and the retention time was 3.30 minutes. The limit of detection and limit of quantification were 0.01 μg/mland 0.04 μg/ml respectively and recovery from different substrates was 92-98%. Therefore, the method is satisfactory and proved to be very precise.
OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The present work is aimed to develop a rapid, simple, sensitive and reliable reverse phase high performance liquid chromatography (RP-HPLC) method of imidacloprid and its residues in different substrates of goat tissues. Separation was achieved using C-18 column with mobile phase consisting of acetonitrile and purified HPLC grade water. The method consists of extracting with acetonitrile from different tissues and cleans up with acetonitrile and hexane (50%) mixture. Quantification was performed by reverse phase (RP) HPLC with PDA detector. The chromatogram showed a well-resolved peak of imidacloprid, and the retention time was 3.30 minutes. The limit of detection and limit of quantification were 0.01 μg/mland 0.04 μg/ml respectively and recovery from different substrates was 92-98%. Therefore, the method is satisfactory and proved to be very precise.
Key concepts: Chromatography, High-performance liquid chromatography, Imidacloprid, Detection limit, Acetonitrile, Chemistry, Hexane, Chromatographic separation