ANALYSIS OF THERMAL BRIDGES' PERFORMANCE OF NEW WINDOWS' INSTALLATION IN THE BUILDING ENVELOPE WITH EXTERNAL THERMAL INSULATION
Mahdieh Abravesh, Behrouz Mohammad Kari
Abstract
Mahdieh Abravesh, Behrouz Mohammad Kari
Abstract
The amount of energy consumption in a building is affected not only by the components’ performance, but also by the building envelope components’ installation have a huge impact on the thermal bridges, increasing the In this paper, the thermal performance corresponding to different positions of the fixed frame, without sub with different sub-frame materials including wood and steel for double these cases, different configurations of thermal insulation have to different models in a sample wall, insulated externally, has been carried out using THERM program. The linear he transfer coefficient has been calculated for each model and the impact of each parameter on the thermal performance has been evaluated. The results show that the position of the frame, the sub thermal insulation around the window frame affects considerably the thermal performance.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The amount of energy consumption in a building is affected not only by the components’ performance, but also by the building envelope components’ installation have a huge impact on the thermal bridges, increasing the In this paper, the thermal performance corresponding to different positions of the fixed frame, without sub with different sub-frame materials including wood and steel for double these cases, different configurations of thermal insulation have to different models in a sample wall, insulated externally, has been carried out using THERM program. The linear he transfer coefficient has been calculated for each model and the impact of each parameter on the thermal performance has been evaluated. The results show that the position of the frame, the sub thermal insulation around the window frame affects considerably the thermal performance.
Key concepts: Thermal bridge, Thermal insulation, Thermal, Thermal transmittance, Building envelope, Dynamic insulation, Envelope (radar), Vacuum insulated panel