2011대한설비공학회 동계학술발표회 논문집Requires access

전산센터에 적용한 외기냉수냉방의 동특성 시뮬레이션

김범수, 김영일, 정광섭

Open publisher page 0 citations

Abstract

Due to high insulation and increased internal heat generation, some buildings require cooling even during winter seasons. One simple way of saving cooling energy consumption is to use a free cooling system when the outdoor air temperature is low. With free cooling system, cooling water is recirculated through the cooling tower to be cooled by the cold outdoor air without operating the chillers. This cooled water is used to cool the indoor space. The design documents of buildings which utilizes the free cooling system are collected and analyzed by using the TRNSYS program. The analysis shows the free cooling system can save energy about 61% compared to the turbo chiller system.

About this research paper

What this paper is about

Due to high insulation and increased internal heat generation, some buildings require cooling even during winter seasons. One simple way of saving cooling energy consumption is to use a free cooling system when the outdoor air temperature is low. With free cooling system, cooling water is recirculated through the cooling tower to be cooled by the cold outdoor air without operating the chillers. This cooled water is used to cool the indoor space. The design documents of buildings which utilizes the free cooling system are collected and analyzed by using the TRNSYS program. The analysis shows the free cooling system can save energy about 61% compared to the turbo chiller system.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Due to high insulation and increased internal heat generation, some buildings require cooling even during winter seasons. One simple way of saving cooling energy consumption is to use a free cooling system when the outdoor air temperature is low. With free cooling system, cooling water is recirculated through the cooling tower to be cooled by the cold outdoor air without operating the chillers. This cooled water is used to cool the indoor space. The design documents of buildings which utilizes the free cooling system are collected and analyzed by using the TRNSYS program. The analysis shows the free cooling system can save energy about 61% compared to the turbo chiller system.

Key concepts: Chiller, TRNSYS, Free cooling, Cooling tower, Water cooling, Environmental science, Evaporative cooler, Active cooling

Back to paper searchBrowse research topicsOriginal source