2003PubMedRequires access

Microtensile bond strength of several adhesive systems to different dentin depths.

Manuel Toledano, Raquel Osorio, Laura Ceballos, Victoria Fuentes, Fernandes Ca, FR Tay, Carvalho Rm

Open publisher page 126 citations

Abstract

PURPOSE: To determine the bond strength of five adhesives systems to either superficial or deep dentin. METHODS: Extracted human third molars had their crowns transversally sectioned either next to the occlusal DEJ or next to the pulp, to expose flat, superficial or deep dentin surfaces. The surfaces were bonded with: 1) three two-step, total-etch, self-priming adhesives (Single Bond, Prime&Bond NT, and Excite), 2) a two-step, self-etching primer (Clearfil SE Bond), and 3) a single-step, self-etching all-in-one adhesive (Etch & Prime 3.0) according to manufacturers' directions. Composite build-ups were constructed incrementally with Z250. After storage for 24 hours in water at 37 degrees C, the teeth were sectioned to obtain several bonded beams of 1.0 mm2 cross-sectional area. Each beam was tested in tension in an Instron machine at 0.5 mm/minute. Results were analyzed by two-way ANOVA and post-hoc multiple comparisons (P = 0.05). Bonded interfaces were also examined by TEM. Nanoleakage was examined using a silver-staining technique. RESULTS: Single Bond, Prime&Bond NT and Clearfil SE Bond performed equally when were bonded to superficial dentin; the lowest value was obtained with Etch & Prime 3.0. On deep dentin, the highest bond strengths were attained with Clearfil SE Bond and Prime & Bond NT. The bond strengths of Prime & Bond NT and Excite were significantly higher to deep than to superficial dentin and the rest of the adhesives showed similar bond strength to both dentin depths. Nanoleakage was manifested to variable extent within all hybrid layers examined.

About this research paper

What this paper is about

PURPOSE: To determine the bond strength of five adhesives systems to either superficial or deep dentin. METHODS: Extracted human third molars had their crowns transversally sectioned either next to the occlusal DEJ or next to the pulp, to expose flat, superficial or deep dentin surfaces. The surfaces were bonded with: 1) three two-step, total-etch, self-priming adhesives (Single Bond, Prime&Bond NT, and Excite), 2) a two-step, self-etching primer (Clearfil SE Bond), and 3) a single-step, self-etching all-in-one adhesive (Etch & Prime 3.0) according to manufacturers' directions. Composite build-ups were constructed incrementally with Z250. After storage for 24 hours in water at 37 degrees C, the teeth were sectioned to obtain several bonded beams of 1.0 mm2 cross-sectional area. Each beam was tested in tension in an Instron machine at 0.5 mm/minute. Results were analyzed by two-way ANOVA and post-hoc multiple comparisons (P = 0.05). Bonded interfaces were also examined by TEM. Nanoleakage was examined using a silver-staining technique. RESULTS: Single Bond, Prime&Bond NT and Clearfil SE Bond performed equally when were bonded to superficial dentin; the lowest value was obtained with Etch & Prime 3.0. On deep dentin, the highest bond strengths were attained with Clearfil SE Bond and Prime & Bond NT. The bond strengths of Prime & Bond NT and Excite were significantly higher to deep than to superficial dentin and the rest of the adhesives showed similar bond strength to both dentin depths. Nanoleakage was manifested to variable extent within all hybrid layers examined.

Why it matters

OpenAlex reports 126 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To determine the bond strength of five adhesives systems to either superficial or deep dentin. METHODS: Extracted human third molars had their crowns transversally sectioned either next to the occlusal DEJ or next to the pulp, to expose flat, superficial or deep dentin surfaces. The surfaces were bonded with: 1) three two-step, total-etch, self-priming adhesives (Single Bond, Prime&Bond NT, and Excite), 2) a two-step, self-etching primer (Clearfil SE Bond), and 3) a single-step, self-etching all-in-one adhesive (Etch & Prime 3.0) according to manufacturers' directions. Composite build-ups were constructed incrementally with Z250. After storage for 24 hours in water at 37 degrees C, the teeth were sectioned to obtain several bonded beams of 1.0 mm2 cross-sectional area. Each beam was tested in tension in an Instron machine at 0.5 mm/minute. Results were analyzed by two-way ANOVA and post-hoc multiple comparisons (P = 0.05). Bonded interfaces were also examined by TEM. Nanoleakage was examined using a silver-staining technique. RESULTS: Single Bond, Prime&Bond NT and Clearfil SE Bond performed equally when were bonded to superficial dentin; the lowest value was obtained with Etch & Prime 3.0. On deep dentin, the highest bond strengths were attained with Clearfil SE Bond and Prime & Bond NT. The bond strengths of Prime & Bond NT and Excite were significantly higher to deep than to superficial dentin and the rest of the adhesives showed similar bond strength to both dentin depths. Nanoleakage was manifested to variable extent within all hybrid layers examined.

Key concepts: Dentin, Bond strength, Adhesive, Single bond, Materials science, Molar, Composite material, Dentistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Microtensile bond strength of several adhesive systems to different dentin depths. — Research Paper | ScholarLens