2011Infoscience (Ecole Polytechnique Fédérale de Lausanne)Open access

Validation of a high-density microelectrode array for acute brain slice recordings

Enrico Ferrea, Lucian Medrihan, Alessandro Maccione, Diego Ghezzi, Pietro Baldelli, Fabio Benfenati, Luca Berdondini

Open full text 0 citations

Abstract

Microelectrode arrays (MEAs) are employed to study extracellular electrical activity in neuronal tissues. Nevertheless, commercially available MEAs provide a limited number of recording sites and do not allow a precise identification of the spatio-temporal characterization of the recorded signal. To overcome this limitation, high density MEAs (HDMEA), based on CMOS technology, were recently developed and validated on dissociated preparations. The platform enables extracellular electrophysiological recordings from 4096 electrodes arranged in a squared area of 2.7 mm x 2.7 mm with inter-electrode distance of 21 μm at a sampling rate of 7.7 kHz/electrode. Here, we demonstrate the performances of this HDMEA platform for the acquisition of electrophysiological activity from acute brain slices. The unique recording performances and the large recording area of the chip permit the observation of fast propagating activities involving multiple areas. In our experimental paradigm, epileptic-like discharges were induced by treating hippocampal slices with 4-aminopyridine and/or bicuculline. The HDMEA allowed us to clearly identify epileptic foci and to describe the involvement of cortical and hippocampal circuitries in the generation of the epileptiform activity. Furthermore, the HDMEA can be coupled with conventional extracellular electrodes for both stimulation and recording, giving the opportunity to perform standard short- and long-term plasticity protocols. We also show that HDMEA can be used in combination with fluorescence live imaging techniques such as Voltage Sensitive Dye recordings. The combination of complementary methodologies supports the HDMEA platform validation and paves the way to detailed electrophysiological studies.

Open-access reader

About this research paper

What this paper is about

Microelectrode arrays (MEAs) are employed to study extracellular electrical activity in neuronal tissues. Nevertheless, commercially available MEAs provide a limited number of recording sites and do not allow a precise identification of the spatio-temporal characterization of the recorded signal. To overcome this limitation, high density MEAs (HDMEA), based on CMOS technology, were recently developed and validated on dissociated preparations. The platform enables extracellular electrophysiological recordings from 4096 electrodes arranged in a squared area of 2.7 mm x 2.7 mm with inter-electrode distance of 21 μm at a sampling rate of 7.7 kHz/electrode. Here, we demonstrate the performances of this HDMEA platform for the acquisition of electrophysiological activity from acute brain slices. The unique recording performances and the large recording area of the chip permit the observation of fast propagating activities involving multiple areas. In our experimental paradigm, epileptic-like discharges were induced by treating hippocampal slices with 4-aminopyridine and/or bicuculline. The HDMEA allowed us to clearly identify epileptic foci and to describe the involvement of cortical and hippocampal circuitries in the generation of the epileptiform activity. Furthermore, the HDMEA can be coupled with conventional extracellular electrodes for both stimulation and recording, giving the opportunity to perform standard short- and long-term plasticity protocols. We also show that HDMEA can be used in combination with fluorescence live imaging techniques such as Voltage Sensitive Dye recordings. The combination of complementary methodologies supports the HDMEA platform validation and paves the way to detailed electrophysiological studies.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Microelectrode arrays (MEAs) are employed to study extracellular electrical activity in neuronal tissues. Nevertheless, commercially available MEAs provide a limited number of recording sites and do not allow a precise identification of the spatio-temporal characterization of the recorded signal. To overcome this limitation, high density MEAs (HDMEA), based on CMOS technology, were recently developed and validated on dissociated preparations. The platform enables extracellular electrophysiological recordings from 4096 electrodes arranged in a squared area of 2.7 mm x 2.7 mm with inter-electrode distance of 21 μm at a sampling rate of 7.7 kHz/electrode. Here, we demonstrate the performances of this HDMEA platform for the acquisition of electrophysiological activity from acute brain slices. The unique recording performances and the large recording area of the chip permit the observation of fast propagating activities involving multiple areas. In our experimental paradigm, epileptic-like discharges were induced by treating hippocampal slices with 4-aminopyridine and/or bicuculline. The HDMEA allowed us to clearly identify epileptic foci and to describe the involvement of cortical and hippocampal circuitries in the generation of the epileptiform activity. Furthermore, the HDMEA can be coupled with conventional extracellular electrodes for both stimulation and recording, giving the opportunity to perform standard short- and long-term plasticity protocols. We also show that HDMEA can be used in combination with fluorescence live imaging techniques such as Voltage Sensitive Dye recordings. The combination of complementary methodologies supports the HDMEA platform validation and paves the way to detailed electrophysiological studies.

Key concepts: Microelectrode, Electrophysiology, Multielectrode array, Hippocampal formation, Neuroscience, SIGNAL (programming language), Bicuculline, Slice preparation

Related papers

Back to paper searchBrowse research topicsOriginal source
Validation of a high-density microelectrode array for acute brain slice recordings — Research Paper | ScholarLens