Functional comparison of upper extremity amputees using myoelectric and conventional prostheses.
R B Stein, M Walley
Abstract
R B Stein, M Walley
Abstract
Upper extremity amputees were tested on a standardized series of tasks using a myoelectric hand, a conventional prosthesis (cable-controlled hook), and their normal hand (unilateral amputees only). They answered also a questionnaire on activities of daily living (ADL) and provided other prosthetic information. Amputees who had been fitted only with a conventional prosthesis, and used their prosthesis regularly, tended to wear the prosthesis more hours per day (14 hours) than amputees fitted with a myoelectric hand (9.6 hours), some of whom continued to use a conventional prosthesis for some jobs. However, the amputees with myoelectric prostheses had a greater functional range of motion (ROM) than those with a conventional prosthesis, and many regular wearers of a myoelectric prosthesis had long since rejected a conventional prosthesis. Amputees took about 2.5 times as long to complete the tasks tested with a conventional prosthesis and about five times as long with a myoelectric prosthesis than with their normal hand. Despite the slower function, more than 60% of below-elbow (B-E) amputees accepted the myoelectric prosthesis in preference to a conventional prosthesis, which they had all been fitted with previously. Others preferred to continue using a conventional prosthesis to which they had become accustomed (13%) or no prosthesis (26%). The combination of function, ROM, and cosmetic appearance of a myoelectric prosthesis is preferred by most B-E amputees, despite its slower performance at the present time.
OpenAlex reports 92 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Upper extremity amputees were tested on a standardized series of tasks using a myoelectric hand, a conventional prosthesis (cable-controlled hook), and their normal hand (unilateral amputees only). They answered also a questionnaire on activities of daily living (ADL) and provided other prosthetic information. Amputees who had been fitted only with a conventional prosthesis, and used their prosthesis regularly, tended to wear the prosthesis more hours per day (14 hours) than amputees fitted with a myoelectric hand (9.6 hours), some of whom continued to use a conventional prosthesis for some jobs. However, the amputees with myoelectric prostheses had a greater functional range of motion (ROM) than those with a conventional prosthesis, and many regular wearers of a myoelectric prosthesis had long since rejected a conventional prosthesis. Amputees took about 2.5 times as long to complete the tasks tested with a conventional prosthesis and about five times as long with a myoelectric prosthesis than with their normal hand. Despite the slower function, more than 60% of below-elbow (B-E) amputees accepted the myoelectric prosthesis in preference to a conventional prosthesis, which they had all been fitted with previously. Others preferred to continue using a conventional prosthesis to which they had become accustomed (13%) or no prosthesis (26%). The combination of function, ROM, and cosmetic appearance of a myoelectric prosthesis is preferred by most B-E amputees, despite its slower performance at the present time.
Key concepts: Prosthesis, Medicine, Elbow, Neural Prosthesis, Physical medicine and rehabilitation, Physical therapy, Surgery, Biomedical engineering