2001Journal of AOAC InternationalOpen access

Determination of Manganese in Feedstuffs by Flow Injection Spectrophotometry Based on Rapid Formation of Permanganate at Room Temperature

Jingfu Liu, Ying-Di Feng, Guibin Jiang

Open full text 8 citations

Abstract

A simple and rapid flow injection spectrophotometric procedure was developed for determination of manganese. In the presence of pyrophosphate and acetate, manganese was immediately oxidized to permanganate by periodate at room temperature in slightly alkaline medium. Under optimized conditions, the determination was made with a sampling rate of 120/h, a linear range of 0-30 mg/L Mn(II), a detection limit (S/N = 3) of 0.08 mg/L, and a relative standard deviation of 0.6% (n = 11) at 10 mg/L Mn(II). The proposed method was used to determine manganese in trace mineral premixes and feedstuffs. Results agreed well with those obtained by the standard atomic absorption spectroscopy method.

Open-access reader

About this research paper

What this paper is about

A simple and rapid flow injection spectrophotometric procedure was developed for determination of manganese. In the presence of pyrophosphate and acetate, manganese was immediately oxidized to permanganate by periodate at room temperature in slightly alkaline medium. Under optimized conditions, the determination was made with a sampling rate of 120/h, a linear range of 0-30 mg/L Mn(II), a detection limit (S/N = 3) of 0.08 mg/L, and a relative standard deviation of 0.6% (n = 11) at 10 mg/L Mn(II). The proposed method was used to determine manganese in trace mineral premixes and feedstuffs. Results agreed well with those obtained by the standard atomic absorption spectroscopy method.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A simple and rapid flow injection spectrophotometric procedure was developed for determination of manganese. In the presence of pyrophosphate and acetate, manganese was immediately oxidized to permanganate by periodate at room temperature in slightly alkaline medium. Under optimized conditions, the determination was made with a sampling rate of 120/h, a linear range of 0-30 mg/L Mn(II), a detection limit (S/N = 3) of 0.08 mg/L, and a relative standard deviation of 0.6% (n = 11) at 10 mg/L Mn(II). The proposed method was used to determine manganese in trace mineral premixes and feedstuffs. Results agreed well with those obtained by the standard atomic absorption spectroscopy method.

Key concepts: Manganese, Permanganate, Chemistry, Detection limit, Spectrophotometry, Relative standard deviation, Potassium permanganate, Atomic absorption spectroscopy

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Manganese in Feedstuffs by Flow Injection Spectrophotometry Based on Rapid Formation of Permanganate at Room Temperature — Research Paper | ScholarLens